VER 5.80.52 6.03.2014
1077. Program Run Options
dialog modified, also dry run allows to fast run without moves simulation (or
just data points), but with checking non-probe moves collisions.
1076. Message about missing
or not calibrated probes is removed when starting cnc Dry Run (will appear only
for on-line Run).
1075. F8 function key make
the 3d view centre to the feature pointed by the mouse cursor in the feature list
window.
1074. Edge Point feature
definition on CAD with mouse right button, program re-places two data points so
they are in default separation from edge (General Options-Surfaces-Edge Point
parameters)
1073. Some occurrences of
wrong cad surface assignment to the imported Surface Points from a text file.
VER 5.80.51 1.02.2013
1072. Excel export, cell
number format corrected in case of system decimal point otter than ‘.’ (DOT).
1071. Surface/Edge point
features, corrections made in search for a cad surface functions.
VER 5.80.50 18.11.2012
1070. Pipe end points
envelope deviations calculation modified, so the error value is calculated in
nominal end position, not the measured end. The difference is when the pipe
ends are not cut off to its nominal lengths.
VER 5.80.49 16.04.2012
1069. Symmetry Tolerance
feature calculation corrected for two planes case.
1068. Angle feature result
box in dimensions mode corrected so it displays Ang- result if selected in the
Nominals dialog.
VER 5.80.48 10.08.2011
1067. Result boxes options,
‘Save as default’ corrected for 'Use Dimensions' and 'Hide not visible SP boxes' options.
VER 5.80.47 13.07.2011
1066. Pipe EndPoint probe
correction was not re-set to the last straight cylinder feature, when
re-generating pipe with different number of straights.
VER 5.80.46 1.04.2011
1065. PH_Cal2 program
corrected so it use default touch speed
1064. Probe model 2nd
and 3rd stylus extensions were not saved with probe file, so they
didn’t appear after reloading a part. Probe file version changed. (12.01.11)
VER 5.80.45 17.11.2010
1063. Chinese
Traditional language selection added.
1062. Multiple
nominals dialog, excusive results selection corrected (radius/diameter)
1061. Error when
selecting probes, if mouse mode enabled (in MW wire frame).
VER 5.80.44 11.11.2010
1060. Change in
memory management, application memory optimized after loading cad files.
1059. Back to the
previous dongle driver with support for parallel port dongle.
VER 5.80.43 1.11.2010
1058. PH1 probe model added.
VER 5.80.42 24.10.2010
1057. New dongle driver for USB dongle only.
1056. Intersection
Cylinder-Plane, corrected setting up last results set when changing result type
from Circle to Point in the Data dialog. Also program remember last type used,
also first/second intersection point in other cases.
1055. Probe diameter
added to the mot_CNCProbewith interface function.
1054. Corrected
blending moves sequence interrupt if SetMotionParams command with blending=None
is executed.
VER 5.80.41 4.10.2010
VER 5.80.40 30.09.2010
Maintenance versions.
VER 5.80.39 8.09.2010
1053. Plane
direction corrected when taken in CAD Surface Mode, with the Initial Alignment
active.
1052. CAD reference
system transformation after alignment was not updated in solid view (since ver
5.80.36)
VER 5.80.38 2.08.2010
1051. Corrections in
cnc RepeatGrid execution for working with slots.
VER 5.80.37 27.07.2010
1050. Axel.ini file
option for displaying solid view result boxes with Chinese traditional
characters.
VER 5.80.36 22.07.2010
1049. Recalculation
of feature list corrected, in some particular case, when a reference system of
a feature was defined later on the list than the feature itself, and the
coordinates was used indirectly (by other construction features) to the feature
definition.
VER 5.80.35 21.07.2010
1048. Error in CNC
editor when saving a new sequence program during learn.
VER 5.80.34 15.07.2010
1047. Updating
Surface Points procedure and messages changed. The command is called manually
from Edit menu or automatically after loading CAD mode, if any surface points
are found to have unassigned its CAD surface reference.
1046. Fix in Angle
feature calculation, is some particular configuration it was causing large
extents for drawing.
VER 5.80.33 14.07.2010
1045. If part file
written with ver older than 5.80.25 and loaded with ver 5.80.25 – 5.80.32, and
if nominal values was defined in [deg] for angular results (cos, ang), might have
wrong nominal values after loading the part. Loading the part with ver .33 will
correct the values.
VER 5.80.32 12.07.2010
1044. Results print
preview form, added intol/out of tol features filter. The filter is active only
when printing from this preview form.
1043. Sizeable Part
Properties dialog.
1042. Save/Load cnc
part with user programs placed in other than standard (PROG) folder. Now the
part saves full path to the program files (ref. ‘Saving Cnc program files with
Part.doc’)
VER 5.80.31 8.07.2010
1041. Part
Properties dialog changed to sizeable
1040. Chinese
characters of the feature names in the result boxes display corrected in case
of Axel in English, but on Chinese windows system.
1039. Sizable dialog
and saved column widths of the command parameters dialog, and UserRes feature
data dialog.
1038. Cnc editor
command box, probe tip angles added to name in the Value column display.
1037. Probes file
name added to the calibration dislogs caption.
1036. Surf_TP_ macro
corrected, now takes probe diameter into account
1035. UserRes
feature error whith long fetaure names in data expression.
VER 5.80.30 1.07.2010
1034. Create new
probe dialog, option to open model edit dialog automatically.
1033. Cnc Calculate
variables for setting probe offsets from the program.
VER 5.80.29 28.06.2010
1032. Part name and
date added to each page of the printout bottom line.
1031. Adding New
probe in multiprobe mode, a theoretical offset to the reference probe is calculated
after model change (tip), when invalidating its positions.
VER 5.80.28 21.06.2010
1030. New sound
added for Message cnc command.
1029. Current Probes
File name is diaplyed in Calibration Sphere Setup and Autocalibration dialogs.
1028. There is a warning
and question box when loading part was saved with different Probes File. There
is and option to keep current probes.
1027. Cnc
Calibration prorgam (ph_cal2) is now always touching the sphere in
perpendicular directions.
1026.
Autocalibration dialog shows sphericity value of measured calibration sphere,
for each calibrated tip position (in the Status tab, and Probe Positions Tab).
These values are not saved to the file yet.
1025. Global options
: ‘Distace absolute results’ and ‘Radial Position Tolerances’ are saved with
the Part.
1024. Starting CNC
program, if any of probes used in the program don’t exists ot are not
calibrated, there is a message warning box.
1023. Nominal values
of the feature angular results are recalculated when changing result type
between cosines and degrees format in the options.
VER 5.80.27 15.06.2010
1022. Probe
Autocalibration, if Single Probe Mode is not selected (in the Probes Manager
dialog), the autocalibration grid displays only cnc positions used with the
current probe.
In Single Probe Mode
it shows also positions used in other probes.
VER 5.80.26 9.06.2010
1021. Probe
Autocalibration, corrected selection of cnc tips in case of multiple probe
heads.
1020. Feature index
number column added to the feature list window.
1019. Probes file
name (*.PRB)is now saved with the part. It will be loaded when loading the
part.
1018. PH10T model
corrected (wrong rotation)
1017. Surface/Edge
point feature can be use in Projection construction
VER 5.80.25 2.06.2010
1016. UserRes feature
recalculation corrected
VER 5.80.24 22.05.2010
1015. Iges surface
corrected (FW34058_A.igs)
1014. Position
tolerance feature, small rounding problem with value of the position
1013.
Autocalibration dialog, separate switch for selecting not calibrated tips only.
VER 5.80.23 18.05.2010
1012. Error opening
nominals table for constructed circle feature (after mod. 994)
1011. Feature
nominals recalculated when changing result type Cartesian-Polar
1010. CAD collision
data saved with the AXD file
1009. ARC_TP3
modified
1007. CNC editor,
corrected Ctrl multiple Execute command selection for multiple edit (was ok for
other type of commands)
1007. CNC editor,
Edit menu option for display consecutive command numbers
1006. CNC editor,
ProbeSel command show PH angled in the title line
VER 5.80.22 10.05.2010
1005. Inch units,
learn mode, when program inserted ProbeSel command, it was filled with values
in mm, corrected to inches.
VER 5.80.21 10.05.2010
1005. Drawing of
selected coord system in 3d view changed, now axes keeps its colours, but they
are bigger.
1004. A bit faster
execution of the cnc program when starting from user start point inside the
program rather than from the beginning.
1003. PosMmc result
of the circle is always calculated as 2D, referenced to the circle projection
plane
1002. Mod 996
reverted to previous state, the bonus is always calculated from diameter.
1001. Arc_tpi3,
arctpo3, arc_pla4 standard programs modified, negative value of cir_margin
changes path to ‘groove’ mode, where program moves out of the hole to the entry
level after each data point.
1000. Cnc command
parameters box border changed to usersizable.
999. Rotation
feature data extended with option of user input of the angle as tangent, ang =
arctan(a/b).
998. Features Insert
mode changed. Now a new feature is added after the selected feature. Except if
this is first or last on the list, then insert is made before selected.
VER 5.80.20 6.05.2010
997. Surface Point
can be used for cnstructing other features in Data Points Source Mode (for use
of uncorrected DP coordinates)
VER
5.80.19 6.05.2010
996. Mmc bonus in
case of radial position toleraces (single sided) is calculated from Radius as a
size. The bonus becomes half of the one in case of diametric pos. tolerances.
995. Position
Tolerance feature displays aditional ‘Bonus’ result, but only in case of MMC
option seelcted.
994. Circle results
– added PosMmc result. User can select Pos OR PosMmc for display.
993. Correction of
DryRun probe collisions and backoff, in case of small probe and backoff value.
992. Using Surface
Point for constructions of other features. Now it uses coordinates SP on
surface, previously it was corrected DP.
VER 5.80.18 9.04.2010
991. Runout Tolerance
for single Circle feature data entry (= position + roundness).
990. Printout date
replaced by Measured date and time. It is most recent feature measurement time.
989. Possibility of
an Application error while loading part that automatically imports iges file,
VER 5.80.17 31.03.2010
988. Position and
Concentricity tolerance features corrected so don’t need recalculate after
change ‘Single sided tolerance’ option, or after loading Part.
VER 5.80.16 29.03.2010
987. New interface
driver dtl_enc7480
VER 5.80.15 25.02.2010
986. Initial
Alignment indication displayed in the Working System status bar field.
985. Correction of
geometric features nominals defined from CAD with Initial Alignment active.
VER 5.80.14 08.01.2010
984. Calculation of
tolerance features gives an error ‘Bad reference data’ when total number of
features exceeds 256.
983. Pipe brackets
default size set back to 10mm, if accidentally the value is =0.
VER 5.80.13 01.12.2009
982. Small change in BestFit system calculation algorithm which should
improve correct solution finding in bad conditions (in example small angle
3-pts pipe)
VER 5.80.12 26.11.2009
981. Pipe bracket
nominal was not generated correctly if its centre lies exactly on the pipe
segment axis.
VER 5.80.11 16.11.2009
981. Line calculated
with plane projection (not 3D) might in some case have wrong projected
direction.
VER 5.80.10 12.11.2009
980. Pipe bracket
nominal data was not generated correctly if its centre was outside of the last
pipe segment length.
VER 5.80.09 03.11.2009
979. Excel export
template new surface points table columns format
Current :
data_sptable = XYZ
measured + DnXYZ deviations + Dn + UT + LT
New :
data_sptable1 = XYZ nominal + XYZ deviations + Dn + UT +
LT
data_sptable2 = XYZ measured + XYZ nominal + XYZ deviations +
Dn +
UT + LT
978. Improved
creating cylinder and cone from the cad (surface mode).
VER 5.80.08 18.09.2009
979. Geometry Transparency
corrected so surface points would be visible if hidden under the surface mesh.
VER 5.80.07 17.09.2009
978. Scrolling added
to the Measure Window view tabs, if there is more tabs than the window width
VER 5.80.06 13.08.2009
978. Some memory
issues corrected for loading iges with big number of entitles.
977. UserRes feature
‘Note’ property added
VER 5.80.05 29.07.2009
976. Circle filter
(968) calculation changed (% of data points).
VER 5.80.04 23.07.2009
975. Modification
968 corrected
VER 5.80.03 21.07.2009
974. Standard
printout feature header, number of points cut to one number – valid points used
for calculation.
973. Modification
968 corrected
VER 5.80.02 09.07.2009
972. Iges import
Offset Surface entity corrections.
971. Points Mode
error when clicked outside the highlighted point.
970. Camera probe,
option for unlock all 3 coordinates. Some transparency added to the camera view
picture.
VER 5.80.01 09.07.2009
969. Points/Edge Mode feature definition from cad entities modified to
have the points coordinates with maximum possible accuracy.
VER 5.80.00 06.07.2009
968. A new option
for circle/arc calculation, which filters out 2 data points, (R min and R max
comparing to the centre calculated with all data points). The option can be
enabled in the main program options General Tab page.
967. Corrected the
Image probe enable state during cnc move with probe on.
966. Feature Insert
mode with Repeat mode ON will add a new feature after, rather tan before
selected feature.
VER 5.79.99 09.06.2009
965. IGES Offset
Surface (140) entity corrected for surface point calculations.
VER 5.79.95 10.04.2009
964. Another
correction of SP automatic selection of CAD surface when measuring a new SP
from the machine. There is second surface search after a correction point is
received.
VER 5.79.94 31.03.2009
963. Occasional
program error during loading a part file.
962. SP Surface
selection modification (the same subject as p.961)
VER 5.79.93 25.03.2009
961. Correction in routine
assigning a cad surface for a new surface point measured on the machine.
VER 5.79.92 26.02.2009
960. DTL_UCC1.dll
driver ver 6.4.16
959. Corrected
calculation of Surface Point in case of folded surface (a wing)
958. Drawing of zoom
rectangle in solid view corrected for Vista system.
VER 5.79.91 26.01.2009
957. Single Move
command didn’t start if there was the starting point defined somewhere in the
cnc program (the green arrow)
956. Correction of
the Edge Point touch depth calculation for the acceptance test.
VER 5.79.90 10.12.2008
955. [internal] Next
stage of presetter interface implemented.
VER 5.79.89 1.12.2008
954. Results save to
file option, date and time uses default windows delimiter characters.
VER 5.79.88 24.11.2008
953. Standard
Results Printout corrected. Page contents overrides bottom page margin if any
features on the page had its Printout Note enabled. This was visible only with
‘Feature Separation Lines’ option checked (general options- Printout tab)
VER 5.79.87 11.11.2008
952. In global
options, CNC Commands tab, additional parameter added for plane radius margin,
it is used when generating arc with round plane command parameters.
951. Overrun
parameter in autocalibration was not correctly passed to the actual program
950. Position
feature with MMC option defined is now automatically recalculated after editing
the nominals
VER 5.79.86 06.11.2008
949. Plane picture
in 3d mode shows an arrow in the centre to give the plane direction. It appears
only when the plane is selected, and Data Points are enabled to show in the
Measure Window view options.
948. Cnc path
drawing in 3d mode uses some different lines (thin dotted lines for simple
moves).
947. Direction of a
plane (touch side) created together with a CAD circle/slot in the Points Mode
corrected.
974. New cnc Learn
dialog disabled from appearing after starting the learn mode.
973. Results-Save to
a text file option, name and date header lines are now left aligned in the
file.
VER 5.79.85 27.10.2008
972. Correction of
mot_CNCProbewith call for the itp interface
VER 5.79.84 22.10.2008
971. Corrections in
PRB files read. Some problems might occurs with files used with ver. from
5.79.66
VER 5.79.83 20.10.2008
970. Projected
2-points line calculation corrected in some special circumstances.
969. Cylinder
feature data points table – deviation values are now displayed with a sign,
like other features.
VER 5.79.82 25.09.2008
968. Selecting features
for coordinate system. When adding (even temporarily by dragging in the measure
window) the same feature as plane and as an axis, Axel was removing the first
feature fro data. Now if for example the same plane feature is selected as
primary plane, and the as an axis direction, calculation of the system will
fail until different feature will be selected.
967. Access
violation when loading a part saved with 3d view set. There was no error if no
part was opened loading another part.
VER 5.79.81 10.09.2008
966. Data Transfer
setup for pipe benders. Situation corrected that if recently used bender was
removed from the benders table, and defined other one in different position in
the table. There was a error message during Data Transfer Enable.
VER 5.79.80 08.09.2008
965. Error in
reading probe PRB file, while loading an old part file (internal part file ver.
< 171, Axel32 release older than 08/2005)
964. [internal]
Support for blended moves added for the Itp interface
VER 5.79.79 03.09.2008
963. ‘Note’ property
added for the tolerance features.
VER 5.79.78 25.08.2008
962. IGES import,
Offset Surface (type 140) support added. Nurbs type of the source surface (128)
is implemented.
VER 5.79.77 11.08.2008
961. Pipe export benders
selection dialog now always appears when there is more than one bender defined.
960. 3D Solid View
window state is now saved and restored with the part.
VER 5.79.76 01.08.2008
959. [internal]
Optimized calculation of line feature (with no projection)
VER 5.79.75 16.07.2008
958. Zoom To Feature
menu command in solid view changed. In this mode selection of a feature changes
the view so the feature is visible in the centre of the window. Rotation and
view scale remains unchanged at the moment.
If the feature has
its view stored, the complete view will be restored (see Feature List, property
tab, View column, RB menu options).
957. Extended search
of the CAD file when loading a part (needed when the part file is moved from
other computer with different import directories). Added function is that AXD
or IGS file is checked in axel default subdirectory (\GEOM)
956. Improvement in
cad surface selection for Surface Point
VER 5.79.74 03.06.2008
955. Pipe with more
than 43 points could cause an error, (TotalLength feature expression too long)
VER 5.79.73 29.05.2008
954. Reading iges
(OC) occasionally gives different characters in entity names. Now each read
should give the same names.
953. Correction of
cad surface entity extents calculation
952. Error in DMS
angle format: minutes (‘) and seconds (“) symbols were at wrong place (numbers
were ok: deg-min-sec)
VER 5.79.72 12.05.2008
951. Deva001 driver
setup corrected, saves driver settings to the dtl_deva001.ini
950. Slot axis
result (cosines) corrected so it display angle values if selected in global
options.
VER 5.79.71 14.03.2008
949. Edge Point
X,Y,Z results nominal values corrected. The nominal values are assigned during
calculation, and represents the edge point coordinates projected onto the CAD
edge.
948. A warning
message added when switching off the BestFit alignment Optimization option.
This normally should be always enabled if using surface points in the best fit
VER 5.79.70 05.03.2008
947. CNC learn, when
creating a standard programs for a feature, it now takes number of points
parameter in following order (next option is used if previous gives 0):
1. ‘No of Data’ feature property
2. Feature actual number of data points
3. Global setting in the Measure Window
options, for given feature type
4. Minimum number of points required for
given feature type
VER 5.79.69 03.03.2008
946. Some features
(i.e. Set feature) might not be rendered in solid view, if they were far from
the machine origin, and the origin was not visible.
This error happened
on ver. 5.79.66
VER 5.79.68 26.02.2008
945. UCC interface correction
for using integrated PHC1050 probe interface card.
945. Solid Probe scanning
update
Reference document: Solid Probe
scanning support.doc
VER 5.79.67 12.02.2008
944. CAD Transformation dialog, resolution of angle inputs increased to
5 dp.
933. Feature Data Points Table inputs of numbers corrected, in case when
Windows decimal character is different than ‘.’ (a dot).
932. Line calculation wrong results, for line feature with projection
property set (correct results for 3D calculation). The error was active since
ver. 5.79.62 (20.12.07)
VER 5.79.66 6.02.2008
931. “Solid Probe Scan” feature property for use with solid probe, in
particular with Faro USB arm and Immersion Red Arm interface.
VER 5.79.65 21.01.2008
930. CNC Program Manager programs tree highlighted font colour corrected
VER 5.79.64 17.01.2008
929. Pipe – option for measuring two square planes instead cylinders.
928. Cylinder construction from two planes (tangent to the planes). Need
user diameter and length.
VER 5.79.63 27.12.2007
927. MCP probe model added
926. 3D probe models – possibility of connecting up to 3 stylus
extensions together in one model.
VER 5.79.62 20.12.2007
925. CAD features extraction modes.
924. Setup- Set Default Desktop menu option for resetting whole desktop
arrangement.
923. Edge mode CAD features extractions
922. Manual calibration dialog displays Sphcty (sphericity) of the
measured calibration sphere. This gives a quality indication of the tip
diameter.
921. Status Working Plane is now in red, if any plane is selected (not
3dD)
920. Adding circle feature from the CAD, program is checking the current
working plane whether to add a new plane for the circle. Previously only
direction of the plane was checked, now also position of the plane.
VER 5.79.61 21.11.2007
919. Translation feature, added construction Line + Point (line
translated to the point)
918. Correction of floating windows position, if accidentally moved out
of the desktop, or if opening the part saved with bigger screen resolution. If
the window will disappear, it should be closed and opened again using Windows
menu option or the toolbar button.
917. Results window – disable/enable data points on the picture
corrected when the window is scrolled down.
VER 5.79.60 18.11.2007
916. Option for default reference length for tolerance features (Measure
Window options dialog)
915. Extended tangent calculation for two circles, (more options to go)
914. Corrected calculation of symmetry tolerance from 3 lines ideally
projected onto the
913. Angle feature without any date, error opening Data property dialog
VER 5.79.59 09.10.2007
912. Possible errors or part file not properly saved if the total file
path was longer than 60 characters.
911. Geometry Transformation, sometimes hangs up the program when
rebuilding 3d geometry objects
VER 5.79.58 01.10.2007
910. Chinese version of Axel Foundation help connected.
907. Feature list window, Property tab, View column.
With the solid view displayed, click LB on this column.
a) If the feature has coloured view icon (feature own view enabled), it
will go to the feature defined view (Execute View in the RB menu), which has
all properties, position, rotation and zoom.
b) If there is no icon, or its greyed (feature own view is disabled),
the view will be scrolled (no rotation or zoom changes), so the feature will be
displayed in the view centre.
906. Angle results display in DMS format. Selected from the main Options
General tab.
Note: at the moment it is only output display, nominal values and
tolerances editors are still in decimal degree format.
VER 5.79.57 20.09.2007
905. BestFit was not calculated correctly with slot feature as a data
904. Results Window error when click mouse LB on empty window, after
deleting a feature
VER 5.79.56 07.09.2007
903. Iges reader, corrected situation that the iges surface has only uv
edge curves specified (no 3d)
In this situation there were no proper edge curves for the Edge Point
calculation.
902. Sometimes an error or hang up occurred after reloading cad to the
part with surface points
VER 5.79.55 04.09.2007
901. Presetter version with another viewer for the image (camera) probe
900. Results Window shows data points and tolerance pictures on the
right side of the table, if the Results Window is docked in the bottom panel.
899. Results Window has a toolbar button for Maximize/Restore window
size, available when the window is not
docked.
VER 5.79.54 24.08.2007
898. Results window – re—enabled function of disable/enable data points
on the feature picture.
LB click : enable/disable point
and recalculate the feature
LB + Ctrl Key : enable/disable,
the feature is recalculated after the Ctrl key is released
VER 5.79.53 20.08.2007
897. Profile feature calculation, for all component surface points with
negative deviations
VER 5.79.52 20.08.2007
896. Long Pipe option – now works with the flange type of end point
construction
895. Extension of T8 temperature interface (average reading)
VER 5.79.51 14.08.2007
894. Symmetry tolerance calculation corrected (case
line-line-plane/line)
893. Symmetry feature corrected – calculation of symmetrical plane
between two lines (or cylinders)
892. Support for reading actual machine temperatures for temperature
compensation (T8 driver)
VER 5.79.50 03.08.2007
891. Profile MaxDev result calculation changed, now it is a difference
between max and min deviations of the particular points. Result name changed to
PrfRes.
890. ZoomAll in 3d view corrected, sometimes showed incorrectly in case
of features with error on the list
889. Cnc MoveTo with probe on corrected inside Repeat-Loop
388. During hardware datum DRO coordinates are now displayed without any
Axel error mapping.
387. Cnc Single Move option added to the Program menu (and toolbar
button)
VER 5.79.48 19.07.2007
386. Corrected line-line symmetry point feature (error in ver 5.79.43)-
effect in wrong pipe calculation
385. Correction of
calculation symmetry tolerance between perfect parallel planes
384. Average Point
polar probe correction – fixed error in case the data points were far from the
point projection plane
VER 5.79.47 17.07.2007
383. Probes manager,
corrected calibration of a newly added probe in Single Probe Mode
VER 5.79.46 5.07.2007
382. Plane-Plane
symmetry feature modified
381. IGES Plane
entity import corrected (with inch iges file)
VER 5.79.45 29.06.2007
380. Symmetry
tolerance feature extended for Point datum
379. International
characters allowed in cnc expressions (ie. Feature name)
378. Error when
closing Coord system definition box with the X button.
VER 5.79.44 21.06.2007
371. Corrections in
the Symmetry tolerance calculations
370. Procounter card
interface
369. Toolbars
Configuration language versions. Names on the Page list (toolbars titles) can
be edited for each language separately.
VER 5.79.43 16.05.2007
368. Introduction of
long pipe split option.
367. Calculation of
Plane-Plane Symmetry feature modified.
366. Overrun and
Underrun parameters added to autocalibration parameters tab. Those values
replaces global Axel setup, just for the calibration program.
365. SLT_RND_PLA and
SLT_RCT_PLA programs modified, so there are additional moves after the plane,
to the point above the slot centre, before start measuring the slot
VER 5.79.42 19.04.2007
364. Corrected
starting axel in command line mode – the parameter is a part name
363. Probes Manager
– Single Probe Mode
In this mode the
probes have no hierarchical structure and there is no offsets between them.
Otherwise (the
Single Probe Mode unchecked) there is one Reference Probe, and the others are
related to it by the Probe Offset calculated during calibration.
362. 3D view –
‘Points Mode’ unblocked when ‘Mouse Rotation Mode’ enabled
VER 5.79.41 08.04.2007
361. Chinese texts update
VER 5.79.40 02.04.2007
360. Chinese texts
update
359. Automatic
add/remove 4th position for probe initial alignment definition, when
changing probe head model to the one with rotation offset (MH20i)
VER 5.79.39 01.04.2007
358. Axel About
dialog display corrected in Chinese version
357. Feature list
window – error after moving more than one feature to the end of list (with the
Alt key)
VER 5.79.38 28.03.2007
356. A question
about invalidating probe positions after change of probe mounting directions
has been added.
355. Second
calibration sphere appeared when opening Calibration Sphere or Automatic Probe
Calibration dialogs, if the sphere already exists on the feature list. At the
moment only one calibration sphere can exist.
354. Reading dongle
corrected on Chinese Windows version
VER 5.79.37 26.03.2007
352. Multiple calibration spheres temporary disabled. Only one sphere
feature can be created using Measure-CalSphere option.
VER 5.79.36 23.03.2007
351. Probes Manager dialog additional Expand button for the probe
changer data.
VER 5.79.35 20.03.2007
350. Automatic calibration dialog, added list of tip positions
349. New calibration sphere setup dialog, modified PH_CAL sequences
348. Chinese version – unexpected data point error during automatic
calibration with search
347. 3D probe models – possibility of connecting up to 3 probe
extensions together in one model.
VER 5.79.34 08.03.2007
346. PH10T 3d probe model corrected
345. CNC editor Learn Mode now allows to edit commands parameters (with
mouse RB)
VER 5.79.33 06.03.2007
344. Automatic plane for Circle feature.
The plane is now not created
when measuring a circle on CAD using RB mouse button data points -
In this case the circle has
projection assigned from the status Working Plane.
Plane is added automatically
only when defying circle in 3d Points Mode.
343. Calibration programs modified (ph_cal2, sph_cal2).
Safety moves enabled to avoid
collision when next position is calibrated on the opposite side of the
Sphere.
Tested also for horizontally
mounted PH probe.
342. MCU1 (ucc) Delete button is now working with the probe calibration
dialog opened (manual calibration).
342. First TP-type probe created on the list is set as the Ref probe.
341. If status Working Plane shows 3D, for new circle, arc, slot feature
it switches to 2D
(one of the coordinate system
planes or plane feature). If the circle centre should not be projected,
it have to be changed later
in the projection property.
VER 5.79.32 28.02.2007
340. Autocalibration corrections :
- reference probe is always
defined after loading older PRB files
- cnc expression return _CALSPHx gives
position of the reference probe cal.sphere
but if the ref probe would
not be defined, it will get current probe.
339. Iges import correction (entity 402, 698.igs)
338. Surface Point surface selection corrected.
There was a case when
direction of correction didn't decide to choose the
surface.
VER 5.79.30 26.02.2007
337. German text file updated
336. Symmetry tolerance feature
335. Autocalibration sphere mounting program parameter added
VER 5.79.29 22.02.2007
334. MCR20 changer programs
323. Probe calibration with different probes (offsets between probes)
322. UCC1 driver corrections, unexpected dp error, move end status flag
321. Initial calibration calculation added for PH type of probe
It calculates probe
directions based on 2 or 3 (MH20) positions declared
in initial calibration tab.
It is recalculated only when the button pressed.
(no automatic calculation
now)
Result of the last
calculation is saved to InitCal(Probename).log file.
320. Probe changer program execution added to manual probe change.
(If not in off-line mode, cnc
program is not running, not in learn mode)
VER 5.79.27 18.02.2007
319. More changer support modifications (new expression variables and functions)
318. Error printing cnc program as text, when there was Message command
with long
multiline text.
317. Calibration subprogram Sph_cal2 correction.
316. Running sphere25 program with 'Show recent number of rows' option
enabled
error fixed.
VER 5.79.26 12.02.2007
315. Probe offsets corrected - between reference and other probes.
Wrong calculations were from
ver 5.79.20 (new probes manager)
314. Write/Read data point to feature data table.
There was a setup in axel.ini
with definition of other reference system and
projection plane for
write/read points to the table.
Now its disabled, it is
always done in ref system displayed in the table without
any projection.
VER 5.79.25 07.02.2007
313. Correction of printed view bitmaps DPI in AxReport.
(set to max 200dpi)
VER 5.79.24 05.02.2007
312. Modification of profile feature with SP points,
Redefined table of results,
drawing in solid view
311. Entities processing.
Menu: Edit-Selection Filter,
while 3d view visible.
Now : for extracting circles
and arcs from surface inside edges and converting to features
310. Sometimes result boxes disappeared after rotation/zoom in 3d.
It was for bigger cad (slower
rendering)
>>>>> VER 5.79.23 ========= xx.xx.2007
===========================================
309.
First version (not working) of entities processing.
Menu: Edit-Selection Filter, while 3d view
visible.
308.
Working Plane and 3D flag.
A new feature has 3d projection flag
disabled even if the status field showed 3d.
This error appeared in ver. 5.79.21
>>>>> VER 5.79.22 ========= 26.01.2007
===========================================
307.
Correction in horizontal arm 3d machine model
>>>>> VER 5.79.21 ========= 24.01.2007
===========================================
306.
Correction p.303 was made with an error, corrected now.
305.
Correction of position of floating windows (Features List, Result Window)
if saved outside screen (might happen if
saved on system with bigger screen
size).
304. New
Probes Manager window with probe changer support - first version.
Reference document: "Probe Changer
support.DOC"
>>>>> VER 5.79.20 ========= 15.01.2007
===========================================
303. Pipe
- prevented against unadjusted B angle being calculated as < -180 deg.
The range in now always -180 .. +180
302.
Corrections about automatic creation of plane when defining a circle from CAD.
If the option "Always create plane
for cad circle" is disabled :
- program takes Working Plane feature
shown the status
(if 3D set, it takes plane that is set
inside the projection dialog)
- calculates a plane from the circle
points
- compares both planes, if they are equal,
a new plane feature is not created
>>>>> VER 5.79.19 ========= 5.01.2007
===========================================
301. A
question box about finishing the Best Fit added when creating the BestFit
with auto-add surface points option
enabled.
300.
Off-line mode is now always disabled when starting with normal Run button.
It was working until now if the first cnc
command was ProbeSel.
299. CNC
editor - Move command that coordinates was learned in off-line mode
are marked with "off" in the
command box, or "M" if read from on-line machine.
298. 3D
view - data points for a feature are visible for selected feature if
Data Points visibility is checked in the
measure window view options.
297.
Measure Window tabs mouse RB menu has now Options item - it is the same as
main menu Setup-Program-Measure Window
296. 3D
sphere picture - default is a full sphere, other option is display part
of the sphere in data points range, or
specified angle range. These options
can be set through "Size and
dir" property.
295.
Error when changing feature type of the symmetry feature.
>>>>> VER 5.79.18 ========= 20.12.2006
===========================================
294.
Keypad interface added for KP_ROUNDSLOT, KP_RECTSLOT, kp_Arc, kp_Set
aux_UpdateKeypad function will be called
every 300ms, and aux_IsKeypadInstalled
function will be checked only when
starting part window.
293.
When starting Axel or making a new part, for cnc systems program will go
to machine mode (disable off-line mode)
292.
Modification in 3d machine model, so model dimensions in 3dmachines.ini
can be omitted if the model is not going
to be scaled
291.
Selected feature in solid view shows its data points as white dots
It shows only probed points (not from
constructions).
290.
Solid view sphere feature picture is now a part of the sphere, according to
the data points range
298.
Change in df_layer for itp interface for loading aux_xxx keypad interface
functions. If the function are not found
in dtl_itp then remain directed
to ax_keypad
>>>>> VER 5.79.17 ========= 14.12.2006
===========================================
297.
DMIS input real numbers are accepted without the digits dot
296.
Symmetry feature corrected picture in solid view
295.
Arc_pla4 cir_startang value was calculated as value > 360 deg
294.
A message box added when measuring first
Surface Point in a new part and
default surface thickness is not zero.
after loading a part with information if
any of the
Surface/Edge points has non-zero Surface
Thickness set.
293.
Pipe - Data Transfer option for zero first and last segment Y
deviation for benders
292.
First version for testing of adding safety moves in cnc learn.
At the moment works when entering a learn
move (MoveTo) or selecting
SurfacePoint feature.
291.
Chinese characters in the result boxes feature name line (solid view)
290.
289.
UCC1 interface corrected
>>>>> VER 5.79.16 ========= 26.11.2006
===========================================
288. Pipe
TWIST angle calculation.
In some cases resulting twist angle was
reversed to have the same sign as
in the nominals.
26.11.06
287.
Pipe generation - brackets are disabled in the BestFit options
22.11.06
286.
Distance feature calculation.
2 lines distance as default is calculated
as 3d space distance.
There is a new option in the Data dialog
for calculating the lines distance
from its midpoints. The two options gives
the same result for parallel lines.
This applies for line, cylinder, cone and
coordinates axis data features.
22.11.06
286. CNC
moves inside RepeatPolar and RepeatGrid corrected
(the move end was calculated with error
depending on Overrun value)
21.11.06
285.
Geometry Transformation
Updated CAD transformation dialog with Apply and Undo operations.
21.11.06
284.
Tolerance features, which has a reference length (perpendicularity,...)
Now when defining the tolerance feature
for the first time, program
automatically set the Reference Length to
size of the first data feature, if
possible (i.e. cylinder, line length - as
calculated from its data points)
20.11.06
283. CNC
Conversion of MoveBy to MoveTo.
It is possible from the graphics window,
when the program picture is visible
(after dry or normal Run).
Switch to "Program" edit mode
(in Status line or Edit menu), and select the move.
More commands can be selected (with the
Ctrl key). If all selected commands
are MoveBy then RB-menu shows option
'Convert MoveBy to MoveTo'.
Commands that have any expression in
dX,dY,dZ parameters are not converted.
16.11.06
>>>>> VER 5.79.15 ========= 13.11.2006
===========================================
282. New
Surface Point of Edge Point feature always takes its Reference System
equal to current CAD ref. system, not the
Working System from the status line.
Surface points require to have the same
reference as the cad for correct
calculations.
>>>>> VER 5.79.14 ========= 9.11.2006
===========================================
281.
Initial calibration function in autocalibration. BETA.
280.
Modification of p.335.
Hardware datum dialog has now disabled
edition of the origin values.
They can be set manually in the axel.ini
file in
[ZeroDlgSetup] section :
ZeroValue0=0
ZeroValue1=0
ZeroValue2=0
279.
PH_CAL2
Sphere program now measres full 90 deg
semisphere (exactly in the equator)
Previously set to 80 deg in p.153
278.
Temperature compensation sign correction
>>>>> VER 5.79.13 ========= 1.11.2006
===========================================
277.
Error in processing iges Surface of Revolution entity
(the error exists from p.263 11.09.06, ver
5.79.8)
>>>>> VER 5.79.12 ========= 24.10.2006
===========================================
276.
UCC1 error mapping (enabled in UCC ini file)
275.
Axel Error Mapping error
There was an error on exit from Axel if
the Error Mapping dislog was used.
>>>>>
VER 5.79.11 ========= 18.10.2006
===========================================
274.
Autocalibration
RB menu option "Calibrate single with
search" option
starts calibration of single position, but
the calibration routine will search
for the calibration sphere down on Z, from
current position. I one data point
is found, program will calibrate the
sphere with bigger margin and avverun
parameters.
273.
Correction of probe length calculation
Offsets recalculation might not be working
for probe head with offset (MH20i)
>>>>> VER 5.79.10 ========= 12.10.2006
===========================================
272.
Pipe - correction of best fit calculation with both end points DN-axis option
_________
12.10.06
>>>>> VER 5.79.9 ========= 12.10.2006
===========================================
271. 3d
Probe models
Added M3 stylus extensions, more M3 styli
models.
_________
10.10.06
270.
Pipe
Shalow angle nominal point option
corrected.
269.
Pipe
Start Point plane intersection option.
Corrected that the P0 intersection
point become an AvrPoint not a Circle.
Cicle was causing wrong nominals
in the Best Fit.
268. CNC
editor - Learn mode
While in Learn Mode,
267.
Excel export
Corrected view export error with named
view cell in Excel, ie part_view_iso
_________
27.09.06
266.
AxReport
Problem with save/load report with feature
result boxes that has
spaces in name
_________
22.09.06
>>>>> VER 5.79.8 ========= 12.09.2006
===========================================
265.
Translation Plane-Point
The plane is translated to the Point
position
264.
Distance calculation
Plane-Plane : distance from the first
plane midpoint to average of data points
of the second plane, (the planes might not
be parallel)
Plane-Line : distance plane - line
midpoint without need to be parallel
Line-Line : average distance fom the two
midpoints projected onto the other line
_________
12.09.06
263.
IGES
Correction of accuracy of Surface of
Revolution iges entity
_________
11.09.06
262. New
CNC command MoveTouch
Takes destination point and approach
direction as parameters.
The command is actually combined two
moves, one to the position with
approach distance parameter away from the
destination, and second - touch
move to the destination point, on the
approach direction.
There is an option in Learn parameters box
for using MoveTouch command for
probed moves - otherwise MoveTo with probe
On is used, which requires
additional move to position probe near the
touch point.
_________
31.08.06
>>>>> VER 5.79.4 ========= 31.08.2006
===========================================
261.
Correction of 3d view internale names of fetaures (errors in chinese version).
_________
24.08.06
>>>>> VER 5.79.3 ========= 24.08.2006
===========================================
260. New
Prgram Run Option for detecting cnc move collision before the move is
actually started.
259.
Correction of display plane in 3d view in some particular orientation
_________
23.08.06
>>>>> VER 5.79.2 ========= 17.08.2006
===========================================
258 Manual Datum operation – LED only to display
the status of datrum, press Start to clear the axes.
257 Fonts in the Datum window –don’t always work
in chinesew window
256 In Chinese version various problems – for
example recoginition of feature names, cross loading of programs between
versions etc.
255 CNC standard program parameters should have
english version only to avoid misinterpretation
254 In Chinese version, we can not implement
probe auto-calibration operation.
253 In Chinese version, in the feature list, when
I want to change the name of a feature, some points are added, because I use
spacebar to select the Chinese words, and the button is assigned to adding
points.
_________
17.08.06
>>>>> VER 5.79.1 ======= 16.08.2006 ============================================
252. New
CNC standard programs for slots with plane :
SLO_RCT_PLA.SEQ
SLO_RND_PLA.SEQ
__________
26.07.06
251. CNC
editor, "Measure to Execute" menu option corrected for some
features (ie. circle)
__________
24.07.06
250.
Correction of surface search for the Surface Point 'Surface' property
In some situations program found surface
with big deviation
(plced on first position of the surfaces
list).
Note: there may be still problems finding
the right surfce, if the
correction direction is significantly
different from the surface normal.
__________
19.07.06
249.
Start Learn error - did not replace existing program if its name was longer
than 8 characters (another program with
the same name was added to the list)
248.
Pipe
Correction in assigning nominals to
fetaures while generate.
Corrected nominal of HP points.
__________
10.07.06
247. Pipe data export external program call
Data Transfer dialog in the Pipe tab
allow to enter external program name.
The program can be selected with the open
dialog (mouse right click).
Also can contain program parameters (full
command line).
If the option is checked, at the end of
writing bender file the external
program will be executed.
(ref.06/04/06)
__________
4.07.06
VER
5.78.10 =====================================================================
246.
Program-Options dialog changed
Added options :
- Animate fetaures views in CNC
This is the same option as in
Setup-Prorgam-OptionsViews tab.
If enabled, during program run 3D view
is changed to the one assiciated
with the fetaure.
The feature view flags are shown in the
features list second tab.
- Show recent number of moves.
If checked, program will show during run
only specified number of last
moves, just to keep the picture clear
247.
Views property of the feature.
The last column of the second tab in the fetaure
list shows view property
assigned to the feature.
Commands an options are available under
the right button menu on this
list column.
Options in the menu :
Store view - fetaure remembers current 3d
view
Execute view - 3D window shows stored
feature view
Disable - stored view is not ececuted
during program run
On Start - feature viev is set when
starting measure the fetaure
On Finish - when feature is finished a
default view is restored
On Both - start measure sets the view,
finis restore default one.
The enabled feature views changes during
cnc program run, or during GO mode,
if selected in the program options Views
tab.
__________
25.06.06
344.
View property in the feature list.
This flag shows if a 3d view point has
been asigned to the feaure. This
view will be visible when feature is
remeasured in Go or CNC mode,
if the function is enabled in
Setup-Option-Views tab.
343.
EP_TP_ sequence modified to touch the edge point relative to the first
surfae point
__________
15.06.06
342.
Surface points that are used in best firt alignment have now its picture
with a black centre (in 3d view).
341.
Corrected calculation of best fit with surface points in CAD initial
alignment mode.
340.
Autocalibration button enabled for the TP probe in its calibration dialog.
339. F2
key does not switch now through the 'mouse' probe (in MW view). The mouse
still can be selected, but using the
ststus bar menu.
19.06.06 The Mod is reversed.
__________
12.06.06
VER
5.78.5 =====================================================================
338.
Edge point acceptance in CNC changed.
In CNC pogram the edge data point is now
always accepted and added to the
feature data, even if its parameters are out
of range (separations, depth).
In manual measuremet not accepted data
point is not added to feature,
and should be measured again.
__________
05.06.06
337.
Introduction release of CNC blending moves (DEVA and UCC1 interface)
__________
01.06.06
336.
Temperature compensation for machine axes and part
Machine coordinates are modified with the
temperature error :
Calculations:
ex = x * (kp * dTp - kx * dTx)
ey = y * (kp * dTp - ky * dTy)
ez = z * (kp * dTp - kz * dTz)
kp - material coefficient of the
part
dTp - temperature difference of the part
kx
- material coefficient for the machine x axis
dTx - temperature difference of the x axis
The three machine axes coefficients are
not editable by user, they
should be set once in the axel.ini file :
[Temperature]
Machine_X_Coef=0
Machine_Y_Coef=0
Machine_Z_Coef=0
335.
Possibility to set datum of the machine to given coordinates.
Axel will set the values in machine
position where the zero was found, or
axis reset manually.
This will work for interfaces with the
cnt_SetCounterVal function implemented.
__________
23.05.06
334.
Multipoits aligment defined on geometric features mod:
- change fetaures nominals and recalculate
bestfit. previously the nominals
were not updated automatically in the
best fit calculation
- remeasure best fit Element, after finish
all features related to element
will be moved to the new transformation
333.
Translation fetaure - second data
If the second component feature is circle
or slot, and it is the same
feature as the first one (the feature has
been selected twice),
then the second fetaure is a direction
plane.
This allows to translate a circle or slot
paralel to itself.
332.
Translation fetaure - slot translation added
331.
Qucker opening multiple feature tolerances dialog (red pencil button)
__________
17.05.06
330.
Feature window - layer field right mouse button menu for quick layer change
329.
Correction in EdgePoint calculation accuracy.
__________
23.04.06
328.
Deleting large CAD is now quicker (ie. when closing part).
(if 3d view was in use)
327.
Application error when selecting a cnc command in the cnc editor, while
3d view not visible.
Might occur in program released between
31.03.06 - 12.04.06
__________
13.04.06
326.
Single feature tolerances dialog.
New option [Meas <-- Nom] - modifies
feature data points so its results
become equal to nominals.
Note:
- this option acutally moves data points
of the feature
- applies only to probe points (not for
constructions)
- uses only positional nominal data,
doesn't change size or direction
__________
11.04.06
325.
Option to lock view in RB property of the MW views tab.
This locks view change and moving results
boxes.
324. 3d
view probe and machine visibility can be switched separately.
Probe is auto-hided in view where tip is
not visible.
__________
5.04.06
332.
Corrections in Axel standard templates for Excel.
Fixed excel export to template created
from once generated report, containing
tables and features.
__________
28.03.06
331.
Program releases btween 17.03.06 and 22.03.06 could not show Set fetaure
drawing in MW view (ie. pipe bends)
330.
Pipe
Nominal table-
when switching between axy and ybc and
there is a question
about recalculate and answer was NO,
program kept info as the nominals was
modified and in consequence when closing
wit OK, the pipe nominals were
updated.
__________
22.03.06
329.
Changes in ARC_PLA4 cnc program
328. Dry
run - the first move is now not simulated, so the probe goes straight to
the move position.
327.
Selecting a command in the cnc editor with the mouse, program now also selects
corresponding feature it this is an
Execute cmd.
326.
Start Learn mode, Message or Pause commands
Causing hangup of the program if in learn
parameters there was checked option
'Execute path and position probe at the
end'
__________
21.03.06
325. CNC
hidden run mode (when starting from a defined point oftheprogeam or
executng run for a single feature), now
does not change probes, until it
gest to the starting point (it was visible
on the screen).
324. CNC
programs
PLA_RND3
ARC_TPI3
Calculation of the last move (out of the
plane and circle) corrected.
Wrong move might appear if the plane dir
was more than 60deg from +Z.
323.
Plane translation feature drawing in 3d view corrected.
__________
16.03.06
321.
Corrected automatic selection of surface for surface points
(when measurin a new sp on the machine)
__________
05.03.06
320.
Layers dialog now shows number of elemens assigned to each layer.
319.
Introduce of Part Mirror option for creating mirrored part fetaures and
cnc programs.
__________
21.02.06
318.
Import Surface Points option now allow to read iges file.
Only entities of iges type Point (116) are
converted into surface point
features.
__________
1.02.06
317. 3D
view - Grid - CoordSystem option corrected.
"Working system" option causes
the 3dview ref system (displayed in the
bottom left corner) to change in sync with
the part working system
(shown in the status bar).
This coordinates effects the grid display
and the View-XY (YZ,ZX)
commands. The 2d command diaplys a plane
of the selected coordinates.
This option is saved with DesktopSave -
this will be restored for the new part,
and independently saved with a part file.
note:
this has no connection with the CAD
coordinate system, which is a reference
of the CAD 3d model read from the cad
file.
__________
31.01.06
316.
Error in Import Surface Points
A line with coordinates in the file was
not accepted if tere was less
than 4 numbers.
Now a point is created if there is at
least 2 numbers in
the
line (xy).
Generally, the line should have 3 or 6
numbers: xyzijk.
The numbers can be separated by any
non-number characters
('0'..'9', ' ', '.', '-', '+', 'E', 'e')
If the ijk direction vector is given, axel
adds a correction point to the
created SP.
The points are referenced to the currnt
working system (from the status line).
__________
26.01.06
315.
Password protection for opening feature data property
(ref.23/01/06)
314.
Pipe results
A case with wrong (+/-) singn of one of
bend values.
(ref.23/01/06)
__________
24.01.06
313.
Rotation fetaure data property dialog corrected
__________
20.01.06
312.
Corection in display grid in 3d view
(it wouldn't show always)
__________
16.01.06
311. Pipe
slot brackets
Bracket types has been extentd by round
and rect slots.
Can be selected globaly in the
'Parameters' page or individually
in the 'Brackets' table in the tast column
(its a 3-state switch working
with dblclick or spacebar)
By defult results enabled for slots are
centre xyz and width.
Generated slot has length equal to with
(its a 'dia' value)
__________
9.01.06
310.
AxRep - fixed error about printer bin
309.
Distance Dist result upper tolerance modified so it doesn't accept
negative number
__________
3.01.06
308.
Enabled possibility of moving fetaures on the list in case of pipe part.
307.
Edge point cnc program EP_PT__.SEQ modified.
Added two parameters to work with 4-point
EP fetaure.
__________
5.12.05
306.
Pipe bestfit end points options
Best fit with point option Dn calculation
has beencorrected.
Now pipe end points can have Dn-axis
option checked (in best fit options
table). This gives correct best fit in
case the end points are shifed
along the tube ends. Only distance to the
tube nominal axis will be taken
into calculation.
Now if there is at last 5 pipe points,
axel enabled Dn end points by
default during pipe generating.
At the moment this function can be
disabled in axel.ini file:
[Pipe]
BfitEndPtDn=0
The Dn optin can be also changed manually
in best fit option property.
__________
9.11.05
305.
Edge point Number of points property added (2 or 4 can be selected)
304. CNC
Learn - Protection against using a standard program for learn.
__________
2.11.05
303. CNC
program during run now also is checking motm_StatusChanged message.
Previously only mot_ReadAxisStatus function
was used during program run.
__________
27.10.05
302.
DMIS slot feature
At the moment axel always creates
rectangular slot
(program W8BHJ07H43 has ROUND parameter,
but measure points fits
rectangular slot)
301.
DMIS probe setup in options
Seyup of dmis probe direction in case
there is no SNSMNT command
in the program.
NOTE : Mounting axis (probe Z) direction
points towards the machine arm
(not the tip end)
Probe X axis is where probe is pointing
whith 90,0 angles
__________
3.10.05
300.
DMIS Alignment Rotation + Plane fixed
289.
DMIS Probes.
This gets a bit more complicated at the
moment.
I have found out that the programs are
probably designed for probe
directions +Y-X-Z (in axel notation),
while itp machine is -Y+X-Z.
Unfortunately the programs doesnt
contain definition of the probe mount,
and all commands SNSDEF has mount axis
0,0,1 (which is equivalent of axel -Z).
As an experiment I have added to the
dmis interface command SNSMNT which
defines all directions of the probe
mount.
It deifnes ZVEC (our AB0 dir) and XVEC
(our A90 dir).
NOTE : dmis ZVEC points towards the
machine, while axel AB0 is along the probe tip (the opposite)
If you put a dmis line in at the
beginning of program :
SNSMNT/XVEC,-1.0,0.0,0.0,ZVEC,0.0,-1.0,0.0,MNTLEN,0.0,0.0,0.0
it defines that the program was
designed for probe +Y-X-Z.
Now the dmis angles will be translated
to the -Y+X-Z (probe which is
set in axel before translation
(DMISProbe)
NOTE : the command is valid inside
single program, so should be added
to each one before translation.
288.
DMIS editor
SAVE menu command enabled
287.
Slot distance and angle calcuation
(distance is from centre point)
__________
30.09.05
286.
DMIS program files loaded with the part file
285.
Axel fff-line joystick mode enabled if pc-joyctick not connected
__________
23.09.05
284. 3D
view RB mouse data points.
Taking data ponits with mouse RB was
sometimes incorrect if the grid
was displayed on top of the cad model.
__________
12.09.05
283.
Correted updat of nominal table bend and radius after editing default
bend and radius in the first tab of the
pipie data dialog.
It was not always updated when changing
mm-inch because of some numbers
rounding.
282.
Pipe - corrected update of pipe points nominals in case of nominals
coordinates start from not 0,0,0 point
__________
2.09.05
281.
Auto-add plane to te circle.
If program adds a plane, and the status
working plane is not 3D, then the plane
become status current working plane.
__________
25.08.05
280.
PH_CAL2 program modified to work correctlty with horizontal arm
(moves between position change)
__________
15.08.05
279.
Pipe - generating pipe with plane intersection end point type there was
no probe diameter used correctly if the
fetaures already existed befor.
generation.
__________
14.07.05
278. New
CNC comands
MoveToRel
MoveByRel
with paraneter RelFetuare, which can be
plane or point.
Move destination point is modified
according to the RelFeature measured
deviation.
__________
12.07.05
277.
Part file version control
In the part open dialog there are
informations about part version number.
One is the part file selected, and the
current one for comparision.
The same information is in Part-Properies-Statistics.
When saving a part that was created with
previous file ver, there is a
message box with information and question
if realy save the file in new
version.
Relation between Axel release verions and
part file versions contain file
part_files_release.txt
276.
Result labels - there is a choice of up to three columns :
measured, nomina, deviations to be
displayed in the box.
Selection is done in the Option-Result
Type checkboxes.
(At least one column is forced to be
selected).
Each column has headre letter above,
respectively M, N, or D
__________
5.07.05
275.
Arc_Pla1 program corrected
(ref. 27/06/05)
__________
28.06.05
274.
Added some pan modes in 3d view with shift key
Menu options\buttons LB LB+Ctrl
LB+Shift LB+Ctr+Shift
----------------------------------------------------------------------------
None - ROT - PAN
Pan mode - PAN - ROT
Mouse rotation mode ROT - PAN -
Mouse rotation mode+ Pan mode PAN - ROT -
Zoom in/out with RB works whenever ROT or
PAN is active.
__________
25.06.05
273.
AxRep - internal limitation for dpi printed of 3d bitmap.
ver 1.3
__________
23.06.05
272.
Auto calibration - order of calibrated tips now set according to the probe
tips list.
271.
Wrong value of pla_angstart of arc_pla4 when created in learn.
270.
Correction of an error in ARC_PLA4.SEQ
__________
16.06.05
269.
Generating pipe - sart and end planes has added correction points
This is important for end with flange,
where direction of first flange
cylinder is determined by circle reference
plane - the flange plane.
__________
10.06.05
268.
IGES import
- A message box added after end of loading
about not processed iges entities
- Added iges offset curve
__________
8.06.05
267.
Pipe flange mods (bends, number of straigts input)
__________
3.06.05
266.
Error in flange construction in GO
Construction of cylinder from a single
circle added 06.09.04
Error with GO from 17.03.05
265.
Pipe file transfer new formats
The same as YBC and XYZ but with pipe
descriptions added.
Format names XYZdescr and YBCdescr (in the
DataTranser setup-File-Format)
__________
31.05.05
264.
Plane feature calculation
If a plane is contructed from point
fetaures, the direction will be
taken form correction of one of the points
to set plane normal side.
263.
PH10 'hand control unit not connected' status was taken as an error and
prevent futher ph communication.
__________
14.05.05
262. OOT
soud disabled for pipe features (points and straights)
261. New
standard program for arc + plane
ARC_PLA4
Added separate angle parameters for a
plane
Correcetd that the arc/circle and plane
fetaures are created during run
if dont exists.
__________
13.05.05
260. Not
reading dro after manual zero of the axis in the datum dialog
__________
11.05.05
259. CAD
initial alignment
The initial alignemt state is indicated in
3d menu, and in the alignmet
dialog ("Active" checkbox).
After defining normal element alignment
this becomes inactive, but the
initial aligment is still remembered.
If for any reason during off-line pfograming
there is a need to revert to
the initial aligment (ie when element
becomes invalid), go to the dialog
and enable "Active" checkbox.
This shows the part back in the initail
alignment regardless of current
element transformation, and allows to
redefine the elmenet.
Part file chenged - Do not read this
ver.files to the erlier versions of Axel.
__________
29.04.05
258.
Plane fetaure diretion calculation
(see p.339)
The probe correction is not used for a
plane constructed from other
features (ie in pipe part). In those cases
the direction is determined
by the component points direction (the
screw rule).
257.
Pipe XYZ-YBC nominal table edition
When switching from XYZ to YBC nominal
table, program saves initial
transformation (first 3 points which
defines elemen system).
When anything changed in YBC and switching
back to XYZ, program recalulates
XYZ that starting from 0,0,0 alog X, and
then adds saved transtormarion.
The efect is that the nominals after that
are still in original xyz datum
ie cad.
Note:
1. At the moment this transformation is
used only in nominals table edition.
When the table is left in the YBC mode,
pipe sill will be generated from 0,0,0
2.
YBC corrections should be made after entering at least 3 xyz point first,
to establich correct initial 3-pts
tranformation (just to see predictable
coordinates in the cad coordiantes)
3. This not applies to 180deg pipe,
because 180pipe is genrated always from
YBC data (from 0,0,0) and at the moment
xyz points cannot be edited.
(ref.21/04/05)
__________
24.04.05
256.
Program sandard sequences for inside slots
SLO_RCT
6pts slot rectangular inside
SLO_RND
6pts slot round inside
__________
20.04.05
255. New
set of standard cnc programs for arc and plane
ARC_TPi3 arc inside
ARC_PLA3 arc inside with plane
PLA_RND3 plane round
ARC_TPo3 arc outside
Has new parameters :
angaxis - index of ref system
axis for ang=0 (x=1, y=2, z=3)
angstart - start angle in deg
ang
- angle value in deg (with sign)
The new program replaces those with
"2" in the name.
Program setup shows only new sequencs to
choose from. Existing
programs using previous sequences are not
afected, until changed executes
manually.
254.
Always start Set feature with 3D projection regardless current status working
plane
__________
11.04.05
253.
Scroll wheel actovated in the CNC editor
252. 3D
geometry rectangle selection
Shift+LB rect selection
Shift+Ctrl+LB rect selection, old selection is not
cleared
If 'Mouse rotation mode' checked
(otherwise Ctrl is used for rotations)
Ctrl+LB toggle selected single entity,
(ref.05/04/05)
__________
07.04.05
251.
Pipe results - corrected [pass]/[fail] calculation.
__________
29.03.05
250.
Off-line Joystick functions
- joystick buttons for zoom in/out
- joystick hat button (POV) controls
rotations of 3d view (by 10 deg)
__________
26.03.05
249.
PH_Cal2 corrected - added an intermediate move up at the end
248.
Axel Joystick (off-line joystick) new options in its setup
- second progamable button, it toggles
joystick function between move
and ph probe selection. These buttons
can be teached, by selecting a
combo box with the mouse and pressing a
joystick button.
- ph probe selection joystick mode can be
enabled in the joystick panel box
It is idicated in the status bar with
different icon.
In this mode ph probe defined position
can be changed with the joystick
(or j. panel buttons)
- 'Disable machine joystick mode when
enable off-line joystik'
This option is enabled by default for
Axel Deva interface, because the
same computer joystick is used by Deva
driver. For other systems where
machine is controlled by a separate
joystick this is not nessesary.
247.
Possible error when loading cnc program using program editor
'Add from file' button
246.
Error opening 3d view with coordinate system feature that has space characters
in the name.
245.
Axel joystick - ph probe positions selection.
Button in the joystick panel box.
__________
21.03.05
244.
Autofinish features on set number of points in MW setup.
Now the feature is not being finished
below its minimum number of points
required for calculation, regardless the
dialog setup.
Ie. circle, plane - 3, cone - 6, cylinder
- 5, sphere - 4. This numbers will
be used if set lower in the setup. (Except
0 which mean no automatic finish).
243.
Iges save corrected for
ciecle
cylinder
cone
Set feature still exported as polyline, no
solid will be seen from
pipe bends.
342.
Corrections for ',' set as decimal point in windows local settings.
__________
17.03.05
341.
Fetaure window program flag indicating existance of Execute or Measure-Finish
command for the feature.
Learn asks now when addidng a feature that already has its Execute or
Measure-Finish commands
__________
15.03.05
340.
ARC_PLA1 program is now selectable for an inside ar program
(arc and plane subprogram).
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
339.
Calculation of Plane feature direction
Now the direction of the plane normal is
determined by its correction dir.
Any order of data points will result the
same plane normal if probed from
the same side.
Plane normal has direction opposite to the
direction of correction/
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
__________
9.03.05
338. 3D
Points mode menu option - no submenu.
Cursor "hand" is shown during
points mode.
Alternative switching the mode on/off is
clicking both LB+RB mouse buttons.
(ref.
10/02/05)
337.
Program cerated in learn for feature now assumes that the fetaure has correct
probe direction, its taken for execute parameters
to decide on which
side to measure from.
Last probe position is no longer taken
into consideration.
336.
There is an option at the start of learn mode that program will be executed
in dry hidden mode, and san path will be
displayed. Axel joystick position
is placed at the end of path, ready for
adding commands.
335. In
edit program mode after dry run parts of the program can be selected
as one piece and display its data in
program property diaog
334. New
feature "Program" propety dockable dialog
with functions for
- edit execute command parameters
- update the parameters with data from the
fetaure
- run single fetaure subprogram
- change subprogram
- delete feature subprogram execute
333. New
toolbars and menu interface
__________
7.03.05
332. 3D
view Pixel Buffer option.
This option uses hardware support for
opengl buffer region extension.
(available for all nvidia based cards)
When enabled program render cad part only
if the scene changes.
If other elements like probe, features,
program, results changes, there is
no need to render cad, so it gives
significant improvement in fram rate.
Reommended for large cad parts and cnc
programs.
331. 3d
view mouse selection changed.
Now iw work like in wireframe MW view, LB
down start selection, mouse move
changes selection to other feature, LB up
accept selection.
This also work in learn, where commands
will be added on mouse up.
330.
Scan path edit - Programs edit mode allow to select single move or
whole sequence for exected sbprogram.
RB menu open command parameters table, or
feature program property dialog
in case of subprogram.
329. 3D
view rotations / framerate
Disabled switching to wireframe when fps
drops down.
Now to speed up rotatiions :
for fps < 5 : ligths disabled
for fps < 2 : depth checking disabled
for fps < 0.1 : hide cad part
__________
22.02.05
328. Cnc
path edit.
Selection scan path in the programs mode
highlights whole subprograms.
Property menu displays data table of
corresponding execute command.
327.
Solid view cad selection.
Added selection with Shift (rectangle) and
Ctrl (add to selection) keys.
This is enabled when RB menu option
'Selection Mode' is checked.
Other function of the Selection Mode is to
show hint box with name of the
surface under the cursor
Rectangle selection (with Shift key) in 3d
solid view work sightly different
than in wire-frame Mwasure Window view.
In 3d all fetatures intersecting with the
rectangle selected are selected,
while in MW only inside and not intersect
are selected.
(ref.10-02-05)
326.
Solid view zoom to window error when selecting a zero sized rectangle
(ref.10-02-05)
__________
12.02.05
325. New
feature nominals not rouded when taking points in 3d RB or points
mode.
Collision points are the same as data
points from the machine and
new nominals are rounded (if set in
general options).
__________
11.02.05
324.
Average Point nominals corrected in some cases, when creating a new
point feature which is autmatically
finished afetr one data point.
323.
Surface point with material thickness
xyz
nominals are set thickness distance from the cad surface
(ref.8-02-05)
__________
8.02.05
322.
Stndard printout setup - Compact mode.
With this option line with table column
heders is printed only once per page.
Useful only for fetures with standard
result table (ie not pipe).
__________
7.02.05
321.
Axel lite
Enabled MW options for show features, data
points and limits.
320.
Correction of slot width results when referenced to other than machine
coord system.
(ref.3-02-05)
__________
3.02.05
319a.
Pipe twist angle calculation
In case of nerly 90 deg twit angles
program looks at nominal points
to establish theoretical directions and
correct B signs, not dependant
on measured values.
319.
Calibration subprogram Sph_cal2.seq corrected
(ref.20-01-05)
__________
24.01.05
318.
Pipe OOT sounds.
Newly generated pipe should not have a
sound on end points and bracket
planes.
(ref.20-01-05)
317.
Guided points
Axial colours.
Option for enabling only point features for
colours an sound
(ref.20-01-05)
__________
22.01.05
317.
Joystick panel - button for bringing joystick probe position into
centre of view
316.
Corrections of guided points
(ref.20-01-05)
315.
Correction of probe calibration alert date calculation
__________
20.01.05
314. DRO
Guided points
Generally in remeasure dro incremental
mode shows a data points measured
last time.
For surface/edge point this is a point
with coordinates on surface,
stored when measured for the first time.
This position is redefined when:
- taking the point from cad
- overwriting manually nominal xyz values
in the tolerance table
(note that the nominals will be
recalcualted with next calculation, bu the
entered position will remain)
Guiding DRO options
- digits colours changing inside two range
area
- sound beeps, when inside range, changes
sound frequency and beep intervals.
__________
16.01.05
313. Fetaure
window cursor keys (keyboard) are disabled if the joystick
control panel is visible
312. DRO
window incremental mode option can be swiched during measurng feature
__________
13.01.05
311.
Default name for pipe points features can be assigned in setup
(features page)
310.
Pipe generation
Corrected pipe points nominals after
generating pipe again on measured
pipe features
__________
10.01.05
309. Cnc
learn
(ref.03-01/05)
hit_tp__.seq program modified so in dry
run when there is no cdata point
there is a move back.
Without this after ending plane program,
current position was inside
part and then added circle was approched
from wrong side.
__________
5.01.05
308.
Standard programs save
Std ptrograms now have blue background in
the cnc editor
Std programs are not automatically saved
with part, also program dos not
ask for save when its modified on close.
The only way to save modified standard
program is to use of Save option
in the cnc editor menu (or toolbar)
{ref.28-10-04)
307.
Sometimes surface wireframes were not visible in the measure window view
after loading iges.
__________
18.12.04
306.
Loosing colision mode when switching probes
(ref.15/10/04)
305.
Catia import
- option for deleting intermediate (iges)
files.
- remember catia file type in the open
dialog
(ref.18-10-04);
304.
Long names in the MEA file export
(ref.19-11-04)
303.
Disbled log window opened when error, withitp interface
Need the axel.ini entry to be empty :
DriverLogFile=
(ref.02-12-04)
302.
Disance absolute result option
(ref.19-11-04)
301. SP
measured in repeat mode, then best fit selected - last empty SP was
added to the best fit. (with auto add SP
to best fit option enebled)
300. 3D
view zoom all - measure SP before part alignemt might casue wrong zoom all
(ref.15/10/04)
__________
10.12.04
299.
Pipe nominals
Changing nominals table for 180 deg pipe,
and closing the dialog with OK
(without generate) was causing wrong data
in the best fit and pipe points
nominals.
(ref.26-11-04)
298.
Pipe brackets
Measured bracket featues are moved up in
the generated fetaure list,
right after measured pipe points.
Brackets are included in the bestfit
components during genetation,
but as default are disbled. Need to be
reset after pipe generation.
(ref.26-11-04)
__________
06.12.04
297.
Correction of PH_CAL2 autocalibration program, it goes above sphere
after each calibrated position, to avoid
collision during change
__________
05.12.04
296. New
cnc program for plane measurement PLA_TPc1.SEQ
(circular)
The program i s selectable in options
-standeard programs and plane
program property dialog.
295. 3D
grid in inch units
304.
Correction of some case of creating plane for circle
__________
22.11.04
303.
Correction of the calibration porgram ph_cal2, there was wrong approach angle
for some
non-90deg positions.
__________
16.11.04
302.
PH9/10 probe off-line mode in joystick mode (doesnt select actual probe
positions).
Off line u can work in ph10. In joystick
mode program doesnt communicate with the machine ph10.
SO you can work in CAD.
301.
Joystick control panel (in menu Windows)
300.
Program property dialog - change program for feature and do dry run of the this
program.
__________
12.11.04
299.
Pipe with brackets - remeasure - corrected finish. Couldnt remeasure brackets.
Program used to finiesh afterthe first
bracket.
298.
Corected initial selection of probe mode when starting part.
Program remembers the last operating mode.
297.
Pipe nominals table input in inch
- pipe
points nominal received wrong values after OK
- input
resolution in inches correted to 5 decimal places
__________
09.11.04
296.
Drawing circle and arc fetaures in 3d corrected/improved for beter visibility
295.
Changed joystick movements. Joystick directions are always relative to the
Measure Window observer.
__________
07.11.04
294.
Joystick button and space bar enabled for enering move in Learn mode, while
3d points mode is acive.
293.
Iges message about hidden layer entities read
__________
22.10.04
292.
Catia import dialog progress bars
291. Initial
CAD alignment for off-line programming
This is a new option in 3d menu, available
when there is no features
aligment for the cad.
The aligment dialog contain option for :
- probe cad plane, this will be aligned to
the machine surface
- flip vertically, rotate and move the
part
Initially placed part should have then
geometrical or surface element alignment
defined (on 3d cad). When the element is
defined, the initial alignemnt
become inactive, but can be used again
once the element is deleted.
The procedure uses some machine setup
parameters, so its good to have
this close to the real machine.
290.
Surface thickness plane property
Surface property for the plane is added if
selectedf in program options
(Surfaces page), and if the plane is
initially measured on the cad.
Plane results are corrected by the
thicknes in the same way as probe correction.
This is applied when the plane is measured
with non- cad points.
__________
22.10.04
289.
Part file restore 3d geometry and feature display mode.
288.
Probe tips selection menu shows calibratio state, similar as in the list
in the calibration dialog.
__________
12.10.04
287.
IGES - some invisible entities from iges now can be found on geometry
hidden layer after iges load.
__________
11.10.04
286.
Error rendering 3d view to a file or report, with reults option
"Hinde not visible SP boxes"
enabled.
285.
Average point dot (small circle) drawing on printout
284.
Part 22XR - problem with calculation plane created for a circle
__________
1.10.04
283. End
of feature sounds
OOT sound is on when :
- tolerances/nominals defined in toler
dialog
- fetuare defined from cad
- pipe features
- GO : fetaures that has measure points
from machine - ie not construction
- no sound for SP, EP at the moment
__________
30.09.04
282.
Reading iges with set feature exported by axel to iges.
__________
29.09.04
281.
Correction in IGES export global section (ie units)
280.
Error calibrating first tip on some systems
279. 3D
features : on top visibility option
278. 3D
geometry : transparency option
277.
Iges export - planes and circles
__________
27.09.04
276.
Error in selecting pages in the setup dialog for systems with some disabled
modules, ie just surfaces enebled.
__________
15.09.04
275.
Surface system have duisablem best fit menu option by mistake since 17.08.04
__________
14.09.04
274.
Pipe points creatd during generating has assigned tolerances from pipe
parameters.
__________
10.09.04
273. New
Dry run in 3d simulation, with colision detection ane unexpected data
point error.
Parameters in menu Program-Options.
__________
08.09.04
272.
Cylinder construction
Cylinder feature can be constructed from
one circle or
circle + point(for length).
Cylinder can now have user diameter (at
the moment used in pipe with flange)
__________
06.09.04
271.
Correction of zoom all in 3D with just features (like pipe) when soe layers
are invisible.
270.
Pipe calculation with HP corrected (eaton_500610_pipe.par).
__________
02.09.04
269.
Best fit restriction options.
Restrictions setup is now preserved when
remeasuring best fit itself,
or its components in GO mode.
__________
01.09.04
268.
Pipe exchange format.
Data points added to the export and import
([DATA POINTS] section)
Kay names:
StartPoint
StartPlane
StartCircle
Straight1
Straight2
Straight3
...
Straightn
EndPoint
EndPlane
EndCircle
Each name is ended by the point number,
ie,
StartPoint_1
Straight1_1
Straight1_2
Following apears depending on end type :
EndPoint - for single or average point,
EndPlane - for plane intesection or flange
EndCircle - for flange
Each line contain 4 or 7 numbers :
x,y,z,d
x,y,z,i,j,k,d
where d is probe diameter (axel might write 0 for generated pipe,
but not measured)
Note: there in no information about
numbero fdata points for a fetaure.
When reading use key name with the next pt
index and see if any not empty
string will be read.
276.
Surface points colours scale display (3d menu)
275. Pipe
exchange format import.
274.
Software control of AB ph10 angles in the calibration window.
The two spins change temporarly values AB,
but actual change of probe
position happen after 1 sec of user
inactivity.
273. New
option for result options for enable result box for new feature.
This option is only for surface/edge
points and circle/arc features.
Note : The option as the boxes itself can
be enabled in each view separately.
272.
Surface points import from text file
A text file with lines
X Y Z i j k
can be imported and surface points for
each such line will be created.
SP will have current working reference
system, and the file coordinates
are assumed to be in this system.
__________
24.08.04
271.
Separate MoveTo button in the program editor - creates MoveTo command
with current probe position in working
system.
270. OOT
sounds modified.
269.
Creating circle plane corrected.
__________
19.08.04
268. 3D
axes in the left corner shows status working system if the option
is checked in 3d
menu-grid-coordinates-current working system.
If this selected do Desktop Save to
remember this setup (at the memoment
this choice in not saved in the part
files).
267.
BestFit alignemnt enabled for pipe module
266.
Circle cerated from cad has now correct nominals.
265.
Fetaure OOT/IT sounds enabled only for fatures with Printout flag on.
264.
Results window buttons hints enabled
__________
17.08.04
263.
Stop GO mode on element, for parts with cnc program.
Was not working with surface points.
__________
11.08.04
262.
Error with SP, when drawing SP in 3D point that has error ie no surface.
Also happened in GO after a data point.
This error appeared after mod. 259.
__________
07.08.04
261.
Autoarange and boxes correction for Set feat.
When result boxes visibility is diasabled,
autoarrnge enables boxes first.
260. A
plane is added to circle cerated in 3d points mode, the same rules
as creating from cad entity in source points
mode.
259. SP
with an error in ResWnd now in 3D view has always OOT colour
258.
Result window shape picture of plane corrected if not on XY
257.
Pipe Flange start/end point option
At the moment work like this:
3pt plane
3pt circle - projected onto the plane
P0 - circle centre projected onto the
straight1
__________
07.08.04
256.
Feature list mod
When selecting a feature as a data for
another feature, now button down
selects the feature (on FL and MW), then
selection can be dragged to other
one, and finally accepted feature is the
one where the mouse button is up.
Function of dragging of features to
another place on the list now works
with the Alt key pressed.
255.
Added pipe end points coorection dir in/out of pipe setup.
__________
02.08.04
254.
Ruled Surface ges read correction (Demo-Part.igs).
253. 2d
view selected box now is red with white text (those coloure are fixed
for now).
252. 3d
view SP picture updated after changing its nominal/tolerance
251.
Autoarrange
Slightly corrected positions of the boxes,
for thr boxes not to loose their
border line when autoarranged on the
window edge. (Might not be 100% proof
because of rescaling the window for
diaplying in the report or printing).
In 3D view box text disappear when its
left edge is outside the window.
Could not fis this at the moment as its
property of the opengl.
250. 3D
view cnc program path visibility option is working
249.
OOT/IT sound.
Program recognizes if the user sets
nominal/tolerance values in the dialog,
or a feature was created using cad and has
nominals set.
In other situation the sound is not
played, until its nominals will be
dfined.
Particulary for pipe there will be no
sound after measure cylinders.
248. 3D
probe cross.
A cross of size 15 mm is displayed when
the probe model is hidden.
The cross is also displayed in collisions
mode (bigger size 30 mm).
247.
Autoarrange
3D view :
- boxes of features with error are
visible, instead of number dsiplays 'err'
and out of tol colour
- autoarrange and lines intersection
corrected
__________
30.07.04
246.
Solid with mesh option in 3d menu for geometry.
__________
28.07.04
245.
Correction of displaying SP surface property list for SP taken with the
mouse on 3d model.
244.
IGES second method of import in program-options
Method1 - axel standard import
Method2 - axel new
__________
25.07.04
243. SP
learn
Update SP execute parameters - corrected
point direction.
242.
Autocalibration routine sph_cal2 :
Probe chenage command moved after the message
about placing the probe
above sphere.
__________
23.07.04
241.
Axel ini now holds parameters for triagulaing iges nurbs surfaces.
[GLUNurbs]
NurbsSamplingMethod=1
NurbsTolerLength=
10
NurbsTolerError=
0.5
This is default setup :
Sampling Method = parametric error (1)
Parametric error = 0.5
Possible methods :
0 - edge legth
1 - parametric error
For 'edge legth' define NurbsTolerLength
value,
for 'parametric error' define NurbsTolerError
This setup is read from ini before each iges
read. Values used for specific
iges file are stored in its LOG file.
At te moment there is no user interface for
changing this oprions.
The bigger values the trialgulation is less
accurate ane there is less trianles.
When trimming errors are visible change of
theis method or value might help.
This apply only for nurbs surfaces (ie not
for cylinder surface).
__________
18.07.04
240.
Axel Report.
- Print 3d axel view while in axel 3d not
initialized, now prints
MW wireframe view.
- Print 3d view scalling corrected.
__________
13.07.04
239.
Colision point detection disabled when cnc program is running
(it was active for the first point after
start axel)
238.
Corrected autoclibration with probe mounted horizintally (ie -Y)
__________
06.07.04
237.
IGES export
At the moment exported features to iges :
- avereage point as iges point (116)
- surface point as iges point (116)
- edge point as iges point (116)
- line as iges line (110)
- set as iges copious data, form 2,
(106)
In the save dialog when iges selected, the
setup button becomes active
and reference system can be selected
there.
In case of the points its coordinates are
corrected as in results.
In case Set feature - they are uncorrected
data points.
__________
01.07.04
236. Set/curve
clipping corrected (drawng in MW)
__________
30.06.04
235.
Pipe remeasure - now remeasure is finished automatically after collectin
number of points equal to N of straights+1
as set in the pipe data dialog.
At the moment it always cerate xyz
nominals, so there is not possible
to remeasure 180 bend pipe.
__________
29.06.04
234.
Round and rectangular slot features
At the moment in results there is no
information for round slot about
situation where there is no straight part
of the slot, ie in case of
wrong data points or so.
__________
24.06.04
233.
Error when starting cnc program from specified start point, and program
displays message box about changing MIH
probe.
232.
Removed sounds when adding feature for coordinate syetem deofinition.
__________
23.06.04
231.
Corection in calculating rotation of a coordinate system.
Loaded part would need recalculation (ie
reclaculate element) to disply
the coordintes correctly. New measurement
will also repair this.
__________
18.06.04
230.
Correction in calibration programs xxx_cal2.seq, situation with
relatively big BaseDia parameter. There is
additional move to not colide
with the sphere.
__________
16.06.04
229.
Results boxes 3d view for SP
There is a result boxes option to hide
boxes of SP that are hidden in 3d view.
This option might need some testing as it
sometimes hides boxes that should
be visible.
228.
Sounds
Added 'end of cnc program' sound. (not in
dry run).
This sound is disabled in AC run, instead
there is IN/OUT of tol sound
at the end of each tip, depending whether
calibration is successfull or not.
227.
Missing True Position result box added in 3d view
226. Saving
back cad to axd acroos the network, now message about the error
225.
Autocalibration in inches corrected
__________
9.06.04
224.
Result boxes arrow line is now in selected colour (if feature selected)
223.
Autoarrange - there was an unnessesary msg about adding another view.
This was happening with result option
display In/Out of tolerance boxes.
222. GO
mode results window now shows previous feature from the current one,
until first data point is collected,
similar to the 'repeat' mode.
__________
5.06.04
221.
Error Saving File during part save if iges was loaded from network or CD.
This was tht axel was trying to save axd
file in the same as iges path.
Now in this case axd ic created in axel
GEOM subdir.
220. Mod
for reading LD100... igs - needs TESTing.
219.
Modifications of SP surface seletion, part meridian1
__________
2.06.04
218.
Protectin against locking light setup in 3d
(also * numerical key brings the light to
the default value)
217. Load
geometry log file is always stored in local axel\geom directory,
not the iges import path.
216.
Modification in SP surfaces dialog and acceptance
Added out-of-boundary value to justify
point position.
Corrected using acceptance range, now its
compared to pure DN value.
Surfaces dialog displays pure DN value and
correction angle, but surface
position on the list is determined also by
out of surface boundary value
(if point is no more than range from the
surface edge)
__________
1.06.04
215.
Corrected SP colour when measuring series of SP (the colour retained
when creating SP in geometry mode).
214.
Corrected display of surface list in SP surface property.
Now autoselected surface is always on the
first position, additionally
there is angle between surface and
correction dir.
213.
Autocalibration - after finishing alibration of non-ref tip program checks
deviation of the calibrated ball from the
reference one. If bigger than
setup dev. - there is a choice to repeat
or continue with the next one.
212.
Serial port initialization corrected for use with pipe result export
__________
31.05.04
211.
Correction in calculating tpi offsets using two calbrated position
Now the calculation shpild be correct for
the probe being not aligned
to the machine axes
210.
Corrected MH8 probe model drawing in 3d
NOTE: Offset Recalulation of the position
for this probe dont work now.
Position needs to be calibrated.
__________
25.05.04
209.
Corrected zoom to fit in 3d, after changing cad coordinate system.
208.
Changed 3d view menu,
"CAD
reference system" now is the same option as Reference Sytem in geometry
mode in
MW. Previous "Coordinates" option has moved to the Grid submenu.
__________
18.05.04
209.
Styli names in 3d probe setup contain styli length
208.
AutoCalibration window openedobly from manual probe setup dialog
207.
Some menu icons were missing
206. CNC
Probesel MIH displaya message box about changing probe position
__________
17.05.04
205.
Corrected drawing of cad acrs in 3d view
__________
6.05.04
204. In
some places axel was checkin status just X axis for common errors
Now added checkig of sum of all axes
ststus.
__________
28.04.04
203. CNC
ExportRes command parameter 'DDE' name changed to 'DataTransfer'
202.
Learn Depth parameter is now added always, regardless of way
the fetuare was created
201.
Correction of feature list
200.
Conetricity tolerance changed
Posiible datum features (datum axis):
circle, arc, line, cylinder, cone
possible feature
a) point, circle, arc,
b) line, cylinder, cone
In case of circle datum, an axis is
constructed from its centre
and reference plane direction.
Two types of concentricity calculation :
a) point distance to the datum axis
b) sum of parallelism value for the
reference length,
and 3d distance between axes.
__________
21.04.04
199. MMC
position tolerance
MMC is enabled for Position tolerance
feature with second feature
as circle.
It takes Nominal, LoTol, UpTol of the
circle diameter.
Positional tolerance is eneterd in the
UpTol of the Position
feature, but results tables display
calculated MMC tolerance im this
position.
198.
Runout tolerance feature
It takes two features data :
1 - line, cylinder, cone
2a - plane,
2b - cylindr, cone
2a - face runout calculated as:
squareness line-plane over the reference
length +
plane flatness (???)
2b - axial runout calulated as :
distance between the two axes in
space (???) +
paralelism of the two axes over the
reference length +
both cylindricity(conicity)
__________
19.04.04
197.
Extension PAA1 added to the probe models
197.
Error map indication for itp in status bar
196.
Printout buttons changed in all features dialog
195. All
types of result boxes in 3d view uses color code for in/out
194.
Feature can be selected with the result box in 3d
193.
Calcel feature tool button changed
__________
18.04.04
192.
Tried to remove multiply page print when more copies set.
Need to check on system where this
happened.
__________
15.04.04
191. Dry
run delay paramater is now saved globally in the INI rather than
individually
for each program.
190.
Fetaure list OK calculation state has now color code (In/OUT of tol)
189.
Result window shape picture - clicking on data points disables /enables
them to calculation
__________
9.04.04
188.
Single side position tolerances setup option (general page)
This option applies to:
- Pos resut of features like point,circle
- Position and Concentricity feature
results
187.
CalcRes feature expression noe allow to use results of SP,EP and
tolerance
features.
__________
5.04.04
186. New
standard program for probe calibration Ph_cal2
185.
Standard programs names setup in the option dialog
184.
There was the same value of accel as speed in the SET MOTION PARAMS
cnc
command which was send to the machine.
183.
property
info box.
__________
2.04.04
182. DRO
probe mode, machine-mouse-axeljoystick switched with F2 can
now be
selected in the status.
181.
Correction in iges load dialog when loading part,
the dialog now closes itself at the end.
180.
Program status line changed to eliminate false texts
__________
3.03.04
179.
Switching off feature result boxes in 3d was not working since 6.01.04
178.
Save cad to AXD in autosave when the axd does not exist yet.
Or, if the geometry transformation or
filter was applied in the meantime.
__________
10.02.04
177.
Printout set/clar additional buttons for all features in printout
confuration dialog
176.
Correction in iges import - paraboloid.igs
__________
29.01.04
175.
Larege numbers apearing in dro window when takin point with
the
mouse RB in 3d view.
__________
22.01.04
174. Pipe
- Inches envelope errors outside tolerance not
highighted
- Tolerance Band [PASS] / [FAIL] text added.
- Supplementary pipe data updated after units
change.
- Result preview window updated after units
change.
__________
14.01.04
173.
HTML export - part name field
__________
13.01.04
172.
Result boxes options (All,In tolerance,Out of tolerance) working in 3D view
171.
Error closing dialog for tolerance edit for multiple features
__________
6.01.04
170.
Error that might occur when cancel not finished fetaure during creating
with
data points source mode, in 3d view
169. CNC
errors
-
program after error always stay in pause, then it can be run or stopped
- cnc
error causes to switch to joystick mode, run or step reenables cnc mode
-
permament error like emergency stop and limits display message box until
the
error dissapears
168.
Pipe nominal table import.
Pipe
data dialog - Load button imports text file which contains nominal data.
Program
reads only lines which contain 3 numbers (separated by comas or space)
The
numbers should be x y z or y b c, depends on the current selection in dialog.
exmpl.
0.000,
0.000, 0.000
10.000,
0.000, 0.000
29.696,
3.473, 0.000
No other
data is read at the moment. Nomber of strights is determined by number
of
correctly read lines.
Other
data like tube diameter and bend radius for a moment have to be set
manually
until file format for those will be defined.
__________
22.12.03
167.
Crash after New part (sometimes after few attepmts)
__________
18.12.03
166.
Fixed difference between points coordinates of the best fit in data table
and
results of surface points used for the calculation.
Before
proper values was those in surface points results.
165.
Result options dialog - "Save as default" checkbox option added for
Results
options are saved for each view separately with the part file
Default
values are used for all views of the New part.
164.
Coordinate systems ignored for zoom all in both MW and 3D views
163.
Axel header in raport text box - date and time placed in the sepearate line
the same
changed in save results to file.
__________
10.12.03
162.
ERROR WHILE EXIT AXEL AFTER USING 3D FIXED
__________
4.12.03
161.
Corrected error with moving ph10 head even when doesn't require change
__________
3.12.03
160.
Additional text info and logo in axe splash bitmap, data in axel.ini
Example
for itp.
[AxelSplash]
User=ITP
EnableUserData=1
Text1=ITP
Text2=www.itpgroup.co.uk
Text3=itp@itpgroup.co.uk
;picure
122x80 pix, no stretch done
Bitmap=itplog3d_small.bmp
159.
AxReport notifies Axel about report file and its disk path. Its location is
now
remembered with part file (previous default search path was 'parts' dir).
Axel
gets the report name in the moment of load/save/close the raport.
__________
27.11.03
158. New
22-characters code to avoid characters mistyping.
(Previous
version of axel still accept 20-char code)
__________
22.11.03
157.
Error excel export (cat housing part)
__________
18.11.03
156.
3-axis joystick support.
Accesible though F2 toggle (a small icon
appears in the probe status)
In Setup menu there is Joystick setup
155.
Fixed error loading MN2501C_ISS3.igs
154.
Corrected depth parameter of subprograms in learn
__________
17.11.03
153.
Automatic calibration
Modifiations
inside calibration program :
-
measure points slightly above the equator (80 deg of the sphere)
-
message about probe psitioning is diaplyed only for the first position
-
corrected moves to avoid the stem
-
increased margin, but later there will be access to this parameter from the
dialog
Calibration
sphere uses its nominal diameter for drawing in MW and 3d instead
of
measured like other features do.
Selection
colour is disabled in 3d for the calibration sphere.
__________
12.11.03
152.
Correction of generated pipe in case od plane projected end points and
first
straight along the Z axis
__________
10.11.03
151.
Save part prompt message after loading cnc program into program editor.
__________
6.11.03
150.
Play sound button in sounds setup fix
149.
Fixed ocasional runtime error when switching to 3d view
148.
Report now is notified about feature name change and 3d view change
147.
Correction of 3d view in element coordinates after read part file
146.
Corrected behaviour of open file dialog in the Stage Errors dialog
__________
28.10.03
145.
Message property dialog of the feature
The
dialog box is closed before feature is deleted.
__________
23.10.03
144.
DTL_PH9 Change in function parameters
Float
changed to double.
DF_PH9
__________
19.10.03
143.
Enabled draw of safety planes in 2d views
This is
for MW view only
(change
of 3rd mouse coordinate -
Ctr+Shift+LBmouse move)
__________
14.10.03
142.
Corrected size of SP picture in 3d. Now the size in mm is the circle
diameter,
the same in pixels.
SP in
exising parts will look 2x smaller, correction in the setup options
may be
needed.
SP
picture setup is stored with the part file (no change there).
141.
Correction of p. 129 - Learn didn't add Measure command with learn
option
Use standard programs enabled.
__________
9.10.03
140.
Dynamic link of DTL_PH9 dll library
__________
8.10.03
VER 5.38
130. Changes
in 3d save bitmap/export regarding bitmap size.
Now
definition of the size is in mm/inch plus selection of dpi.
129. CNC
Learn
With
learn option "Use standard program" switched off, now there is
possibility
of
selecting existing feature from the list (measured erlier), press
remeasure
function (instead of new fetaure). Learn will insert Measure-Finish
comands.
128.
Dongle message appears in front of splash logo
127.
Error with probe file name when named axel.prb
126. 3d
Points mode points can now be selected when geometry is referenced
to any system
125. 3D
model position updated after changing geometry reference system
124.
Result boxes in 3d updated after editing tolerances.
123.
AxReport
Report
was printing previous MW view after change of paty in axel.
Correction
in part name. When axel calls report with a name which contains
spaces,
now the whole name appears in raport correctly.
If print
report is called from axel, program tries to load raport file with
the part
name, if not succesful it tries to load just the template file.
If none
of this is successful, raport prints nothing, but stays opened.
Resulions
of axel bitmaps restricted to 360 dpi.
AxReport
version changed to 1.2
__________
24.09.03
122.
Definig surface point in 3d in geometry mode on selected surface
121.
Space bar pressed on delete last point message box
__________
23.09.03
120.
Bitmap added to standard printout, setup in printout page of
options
dialog. It is a global setup for all parts.
119.
Corrected pipe inch results - last digit rounding
118.
Corrected
__________
12.09.03
118.
Problem with saving DXF file
117.
Fonts of standard printout header lines changed.
__________
09.09.03
116. Corrections
in best fit calc with mindev and maxdev optimization type
__________
30.08.03
115.
Geometry transform dialog, removed change of checkboxes after
coord system change
114.
Increased size of expression string in cnc command
__________
26.08.03
113.
Increased size of expression string in UserRes feature (to 255 characters)
__________
26.08.03
112.
Recent parts dialog, part picture
Picture
can be assigned to the part
a) in part property dialog
b) in 3d view "Save as bitmap"
option -
"bitmap for part preview"
checkbox.
The
picture is not used in printout or report yet.
__________
15.08.03
111.
Sounds setup in options.
Need to
define more events
110.
Corrected buttons bitmaps (in disabled mode, with 16bit colour)
109.
Corrections in 180 bend pipe
-
nominal table xyz Pa,Pb points (but editing is disabled)
- result
boxes for Pa, Pb points
-
corrected generation when 180 bend goes with non-zero twist
- HP
bend point removed from the best fit
__________
17.07.03
108.
Multiple axd geometry files can be added to the part.
Can be
then saved as single axd file. Consecutive files adds an 'a','b'..
letter
to the entity and layer names.
__________
9.07.03
107.
Pipe end points correction
StartPt
and EndPt will be generated with probe correction option set to
"forced".
For
existing parts this can be set manually, the probe correction option
should
be set to :
StartPt: +X, element, forced
EndPt" -X, lasstrightname, forced
106.
Delete last feature on feature list scroller error
105.
Stiefelmayer XR Format for serial data d=transfer
Folowing
setup will send serial data
- serial
port - features - digitizing - Selfaymayer XR
Autotransfer
option will send datapoints of the feature right after its finish.
With
Autotransfer option always last feature data only wil be sent.
When
there is no Autotransfer checked, manual send result will transfer all
features
data or last fetaure depends on Send last feature only option.
If all
efatures are being transfered feature Printout flag is used, when
sending
single fetaure it is done regardless thie flag.
A the
moment there is no signs send at the beginning of feature so all data
point
are contignous set of XYZ and RST lines.
For the
moment there might be a problem with last correction point of the feature
with
Autotransfer option
__________
5.07.03
105.
Correct entity names after adding another iges while keeping
previous
geometry
104.
Dongle when checking time of the previous axel run now ignores
few
minutes differences so it should be posiible to use the dongle on other
computer
without waiting.
103.
Corrected geometry extents after geometry transformation
__________
3.07.03
102.
Automatic ph calibration (first release)
__________
28.06.03
101.
Improved saving positions of toolbars
100.
Proper size picture in excel report
99. Last
zoom (last view) option working in 3d view
__________
20.06.03
98. 2D
views with grid, relative to any coordinate system
__________
19.06.03
97.
Errors in read surfaces from axd, only in versions from 5.06.03
96.
Added Probe selectin window menu item and toolbar button
95. 2D
view menu options and buttons
__________
14.06.03
94. CNC
program stops on motor status error flags even if bit
mots_ON
is still set (0002h)
mots_encoderr
mots_noairpress
mots_zoverspeed
mots_emrgstop
mots_unexpdp
mots_expdpnot
Until
now program report these errors only if at the same time
mots_ON
bit was zero.
__________
12.06.03
93.
Improved time of processing large surfaces while loading iges
__________
10.06.03
92. Pipe
180 deg bends.
Need
check on real nominals example
91.
Corrected load/save to axd with large number of vertexes in surfaces
(102318.igs)
__________
5.06.03
90.
Corrected texts in delete features dialog box
89.
Update pipe in 3d after generate
__________
26.05.03
88. CNC
program- highliht correct command in case of program error
87.
Corrected buttons for edit menu options
86.
Error mapping indication in status bar
85.
Default surface thickness in SP options
__________
20.05.03
VER.
5.33
86.
Removed use of old setup PipeFileDir=c:\axel.exe\parts in pipe directories
85.
SendResults toolbutton enabled
84. Pipe
serial 0 checksum
__________
18.05.03
89.
Corrected some default settings in case of missing axel.ini
88.
Backup of axel.ini (axel.in~) created when starting axel (no automatic restore)
87.
IGE,IGES extension filter in import geometry dialog
86.
AutoZoom feature working in 3d view
85. New
calculation of centre of rotation on 3d after zoom to window
84. New
version of GLU32Axel13.dll
83.
Slightly changed moments of writing probes file
__________
15.05.03
82.
Corrections in surface points from cad
-deviations
are now =0
-correction
dir taken from cad so can be used in learn
__________
7.05.03
81. New Bends_
user res feature in pipe feature list, just to pass
bend
values to other user calculations
80.
Generate pipe from YBC nominal in inch fix
79. SP
execute learn parameters fix
78.
3-pts pipe brackets plane
77. Pipe
serial checksum byte = 0 fix.
__________
28.04.03
76. Pipe
data in inch
75.
Axreport
74.
Toolbars configuration corrected
This was
a case when all pages were set as separate (no tabbed toolbar)
73.
Modification is SP surface search
Now
surface is rejected only if SP lies oustside surface boundary more than
the
search range distance.
__________
16.04.03
72.
Error in print preview
This was
caused by long part name.
71.
Error in 6915110stand250303_3d.igs
This was
a problem with old 16bit integer, a surface has more
parameters
__________
3.04.03
70.
Improvement of polylines selection in 3d
If in
the area of mouse cursor (now its 4x4 pixels) are surfaces and
polylines,
program select polyline.
69. Pipe
serial export
68. Pipe
Plane
defult number of points set to 3.
Pipe
points in feature list labeled P0...Pi
__________
25.03.03
67. Grid
- but options dialog needs more corrections
66. More
corrections in 3d
__________
18.03.03
65.
Error after closing viewpoint dialog with window x button
64. Iges
entities with blank flag set are put to "hidden" geomery layer
62.
Repaired selection colour of polylines in 3d
__________
15.03.03
61.
"Update SP surfaces" menu option in Edit menu for checking surfaces
of
surface points.
It is
also checkes automatically after inporting geometry file.
60. Best
fit deviations dialog disabled in GO and CNC
59. New
comunication betwen axel and report
Only
those versions will work together from now on.
AxReport
is marked with ver 1.1 in its status line.
58.
Corrections in autoarrange
__________
3.03.03
57.
Modificatins in 3d
All
nurbs surfaces rendered by opengl glu (slow rendering)
Added
some unctions for checking trimm correcteness
__________
26.02.03
56. Correction
of created plane for circle when adding points from cad
with
data points source mode.
__________
5.02.03
55.
Error with resources while printing in axel report.
54.
Autoarrange in 3d view
__________
14.01.03
53.
Recalculating SP when loading geometry
Program
finds SP which surfaces no longer exists. Then search for a new surface
and
recalculates the feature.
partname.log
file is writen with informations about surfaces and deviation
changes.
__________
23.12.02
52. Long
names for cnc program files
__________
22.12.02
51.
Points mode in 3d view
50. Pipe
data export to file and serial
__________
20.12.02
49.
Remember last directory of imported geometry file
__________
10.12.02
48.
Rounding error in result display
47.
Remeasure of multipoint best fit
__________
8.12.02
46.
Error printing Min type result boxes from axreport
__________
1.12.02
45.
Error in calbration when axis data has 1 interval
__________
19.11.02
44.
Autoarrange
Nowprogram
doesnt ask if crete another view if not arranged features
have its
origin outside the window.
__________
18.11.02
43.
Opening MW in right size (not minimized) when using Part-Load menu opt.
__________
16.11.02
42. Some
improvements in rendering
__________
14.11.02
41. Errors
reading older part files that read non-existing seq files
40.
Error in EP calculation (in projection onto line entity)
__________
8.11.02
39.
Colours setup for result boxes options
__________
31.10.02
38. Not
loading cad from subdirectory of \geom
37.
Export geometry - save dialog with current cad name
__________
24.10.02
36.
Changes in displaying result boxes in 3d - possible errors
__________
23.10.02
35.
Deactivated SpaceBar point when displaying feature property dialogs
34.
Errors reading bounded surfaces in iges
__________
20.10.02
33. Edge
Point cnc program
Similar
to SP program for edge point Ept_tp__.seq
__________
18.10.02
32.
Nominals XYZ of Surface Point - set at each SP recalculation
__________
4.10.02
31.
Nominals XYZ of Edge Point - set at each EP recalculation
__________
25.09.02
=============
5.19 =================
30.
Enable print one fetaure option in Result Window
29.
Saving to dxf error
Save
surface an edge points to DXF
__________
24.09.02
28.
Errors displaying large program in the cnc editor
__________
24.09.02
27.
Error loading part which was saved with define <element> dialog opened
__________
14.09.02
26.
WIndows 2000 axel problems
-
printing results from axel
- dll
error (reading ini file), causing crash or hangup
__________
10.09.02
25.
Correction of IGES reading
sample
file : JIG-COMPLETE.IGS
what's
wrong : hanging in 3dmesh trimming procedures
24.
Changing surface property of SP
after
change of surface there is a question box whether to update
Execute
comand parameters of this SP, if exists.
__________
29.08.02
23.
Surface selection for SP property
Now
order of the surfaces list is is modified by correction dir.
If the
corr dir is more away from prpendicular to the surface its distance
on the
list is increased and the surface is shifted down on the list.
Surfaces
on non-visible layer are not taken into account.
22.
Axrep correct number of pages display while printing
21.
Finish/Cancel of SP in Learn crash (not always)
__________
21.08.02
20.
Update 3d mesh data after geometry transformation
19.
Surface selection in SP surface dialog in 3D
Selecting
surface in te list in surface property of SP feature
higlights
the surface in the 3d view.
18. IGES
error
Error
while taking surface point (60973kpx15740-00.igs).
The
reason was wrong processing of surface of revolution from iges.
__________
14.08.02
17. Save
MW background color to ini and part file
_______
8.08.02
16.
Error finding surface for SP after cad transformation
15.
Error while loading new part with iges (iges dialog at start)
14.
Crash running german version
_______
7.08.02
13. HTML
template
12.
Update surface points size in 3D after change mm/pixels in options
_______
5.08.02
11.
Error closing data dialog for gauge feature
10.
SURF_TP program modified
The
second move has been removed. Now program goes to the point margin
away
from the surface coordinates, and then is a touch moveby with the
margin
length.
Underrun
and overrun values are not used directly by the subprogram.
9. CNC
Comment editor
There
was an error when accepting edited text of the Comment
_______
1.08.02 5.11
8.
Report
HTML
report can be edited with Front Page.
Measure
Window bitmap is now exported also from MW mode as well as 3D.
7.
Autosave mod
Now save
and autosave dosn't finish learn mode and measured feature.
But
still the part after load will always have learn mode disabled and
no
feature will be active.
_______
30.07.02
6. Autosave
mod
This
saves now only PAR file, without axd geometry file, this should
minimize
interrupts when working with the program.
5.
Feature default name setup in program options
4. New
result box type "Minimum"
This is
always one line box, with fetaure name and a result number.
The
result displayed is the first from the list in reults window - it can
only be
changed by enabling/disabling results in the tolerance table.
_______
16.07.02
3.
Results "Use Dimensions" flag
The flag
is now remembered in te part file, separately for each view.
2. CNC
program time
The cnc
program last execution time is displayed in the status line
after
loading part has been opened from file
1. CNC
editor fix
Display
of large number of commands
_______
10.07.02